. 2011 Aug;2(8):680-8.
doi: 10.1007/s13238-011-1086-2. Epub 2011 Sep 9.

Driving efficiency in a high-throughput metabolic stability assay through a generic high-resolution accurate mass method and automated data mining

Affiliations

Driving efficiency in a high-throughput metabolic stability assay through a generic high-resolution accurate mass method and automated data mining

Wenqing Shui et al. Protein Cell. 2011 Aug.

Abstract

Improving analytical throughput is the focus of many quantitative workflows being developed for early drug discovery. For drug candidate screening, it is common practice to use ultra-high performance liquid chromatography (U-HPLC) coupled with triple quadrupole mass spectrometry. This approach certainly results in short analytical run time; however, in assessing the true throughput, all aspects of the workflow needs to be considered, including instrument optimization and the necessity to re-run samples when information is missed. Here we describe a high-throughput metabolic stability assay with a simplified instrument set-up which significantly improves the overall assay efficiency. In addition, as the data is acquired in a non-biased manner, high information content of both the parent compound and metabolites is gathered at the same time to facilitate the decision of which compounds to proceed through the drug discovery pipeline.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Castro-Perez J., Plumb R., Granger J.H., Beattie I., Joncour K., Wright A. Increasing throughput and information content for in vitro drug metabolism experiments using ultra-performance liquid chromatography coupled to a quadrupole time-of-flight mass spectrometer. Rapid Commun Mass Spectrom. 2005;19:843–848. doi: 10.1002/rcm.1859. - DOI - PubMed
    1. Chu I., Nomeir A.A. Utility of mass spectrometry for invitro ADME assays. Curr Drug Metab. 2006;7:467–477. doi: 10.2174/138920006777697954. - DOI - PubMed
    1. Di L., Kerns E.H., Carter G.T. Drug-like property concepts in pharmaceutical design. Curr Pharm Des. 2009;15:2184–2194. doi: 10.2174/138161209788682479. - DOI - PubMed
    1. Gao H., Materne O.L., Howe D.L., Brummel C.L. Method for rapid metabolite profiling of drug candidates in fresh hepatocytes using liquid chromatography coupled with a hybrid quadrupole linear ion trap. Rapid Commun Mass Spectrom. 2007;21:3683–3693. doi: 10.1002/rcm.3257. - DOI - PubMed
    1. Hu Q., Noll R.J., Li H., Makarov A., Hardman M., Graham Cooks R. The Orbitrap: a new mass spectrometer. J Mass Spectrom. 2005;40:430–443. doi: 10.1002/jms.856. - DOI - PubMed

MeSH terms