A simplified in vivo approach for evaluating the bioabsorbable behavior of candidate stent materials
- PMID: 21905215
- DOI: 10.1002/jbm.b.31922
A simplified in vivo approach for evaluating the bioabsorbable behavior of candidate stent materials
Abstract
Metal stents are commonly used to revascularize occluded arteries. A bioabsorbable metal stent that harmlessly erodes away over time may minimize the normal chronic risks associated with permanent implants. However, there is no simple, low-cost method of introducing candidate materials into the arterial environment. Here, we developed a novel experimental model where a biomaterial wire is implanted into a rat artery lumen (simulating bioabsorbable stent blood contact) or artery wall (simulating bioabsorbable stent matrix contact). We use this model to clarify the corrosion mechanism of iron (≥99.5 wt %), which is a candidate bioabsorbable stent material due to its biocompatibility and mechanical strength. We found that iron wire encapsulation within the arterial wall extracellular matrix resulted in substantial biocorrosion by 22 days, with a voluminous corrosion product retained within the vessel wall at 9 months. In contrast, the blood-contacting luminal implant experienced minimal biocorrosion at 9 months. The importance of arterial blood versus arterial wall contact for regulating biocorrosion was confirmed with magnesium wires. We found that magnesium was highly corroded when placed in the arterial wall but was not corroded when exposed to blood in the arterial lumen for 3 weeks. The results demonstrate the capability of the vascular implantation model to conduct rapid in vivo assessments of vascular biomaterial corrosion behavior and to predict long-term biocorrosion behavior from material analyses. The results also highlight the critical role of the arterial environment (blood vs. matrix contact) in directing the corrosion behavior of biodegradable metals.
Copyright © 2011 Wiley Periodicals, Inc.
Similar articles
-
A new in vitro-in vivo correlation for bioabsorbable magnesium stents from mechanical behavior.Mater Sci Eng C Mater Biol Appl. 2013 Dec 1;33(8):5064-70. doi: 10.1016/j.msec.2013.08.042. Epub 2013 Sep 7. Mater Sci Eng C Mater Biol Appl. 2013. PMID: 24094225
-
MicroCT and contrast-enhanced microCT to study the in vivo degradation behavior and biocompatibility of candidate metallic intravascular stent materials.Acta Biomater. 2025 Jan 1;191:53-65. doi: 10.1016/j.actbio.2024.11.017. Epub 2024 Nov 17. Acta Biomater. 2025. PMID: 39561850
-
Metallic zinc exhibits optimal biocompatibility for bioabsorbable endovascular stents.Mater Sci Eng C Mater Biol Appl. 2015 Nov 1;56:467-72. doi: 10.1016/j.msec.2015.07.022. Epub 2015 Jul 16. Mater Sci Eng C Mater Biol Appl. 2015. PMID: 26249616 Free PMC article.
-
Biodegradable Metals for Cardiovascular Stents: from Clinical Concerns to Recent Zn-Alloys.Adv Healthc Mater. 2016 May;5(10):1121-40. doi: 10.1002/adhm.201501019. Epub 2016 Apr 20. Adv Healthc Mater. 2016. PMID: 27094868 Free PMC article. Review.
-
Materials and manufacturing technologies available for production of a pediatric bioabsorbable stent.Biomed Res Int. 2013;2013:137985. doi: 10.1155/2013/137985. Epub 2013 Sep 8. Biomed Res Int. 2013. PMID: 24089660 Free PMC article. Review.
Cited by
-
Structural and temporal dynamics analysis of zinc-based biomaterials: History, research hotspots and emerging trends.Bioact Mater. 2024 Feb 10;35:306-329. doi: 10.1016/j.bioactmat.2024.01.017. eCollection 2024 May. Bioact Mater. 2024. PMID: 38362138 Free PMC article. Review.
-
Systematical evolution on a Zn-Mg alloy potentially developed for biodegradable cardiovascular stents.J Mater Sci Mater Med. 2019 Nov 1;30(11):122. doi: 10.1007/s10856-019-6324-9. J Mater Sci Mater Med. 2019. PMID: 31677119
-
Mechanical Analysis and Corrosion Analysis of Zinc Alloys for Bioabsorbable Implants for Osteosynthesis.Materials (Basel). 2022 Jan 6;15(2):421. doi: 10.3390/ma15020421. Materials (Basel). 2022. PMID: 35057136 Free PMC article.
-
Biocompatibility and Degradation Behavior of Molybdenum in an In Vivo Rat Model.Materials (Basel). 2021 Dec 16;14(24):7776. doi: 10.3390/ma14247776. Materials (Basel). 2021. PMID: 34947370 Free PMC article.
-
Limitation of Water-Soluble Tetrazolium Salt for the Cytocompatibility Evaluation of Zinc-Based Metals.Materials (Basel). 2021 Oct 20;14(21):6247. doi: 10.3390/ma14216247. Materials (Basel). 2021. PMID: 34771776 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources