Comparative Study
. 2011 Mar-Apr;64(3-4):211-4.
doi: 10.2298/mpns1104211a.

Diode laser trabeculoplasty in open angle glaucoma: 50 micron vs. 100 micron spot size

Affiliations
Comparative Study

Diode laser trabeculoplasty in open angle glaucoma: 50 micron vs. 100 micron spot size

Andreić Veljko et al. Med Pregl. 2011 Mar-Apr.

Abstract

The study was aimed at evaluating the efficacy of diode laser trabeculoplsaty in lowering intraocular pressure in patients with both primary open-angle glaucoma and exfoliation glaucoma by using different size of laser spot. This six-month, unmasked, controlled, prospective study included sixty-two patients with the same number of eyes, who were divided into two groups. Trabeculoplasty was performed with 50 micron and 100 micron laser spot size in the group I and group II, respectively. Other laser parameters were the same for both groups: the wave length of 532 nm, 0.1 second single emission with the power of 600-1200 mW was applied on the 180 degrees of the trabeculum. The mean intraocular pressure decrease in the 50 micron group (group 1) on day 7 was 24% from the baseline and after six-month follow-up period the intraocular pressure decrease was 29.8% (p < 0.001). In the 100 micron group (group II), the mean intraocular pressure decrease on day 7 was 26.5% and after six months it was 39% (p < 0.001).