Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2011 Dec;23(10):685-90.
doi: 10.1016/j.clon.2011.08.007. Epub 2011 Sep 9.

Three-dimensional high dose rate intracavitary image-guided brachytherapy for the treatment of cervical cancer using a hybrid magnetic resonance imaging/computed tomography approach: feasibility and early results

Affiliations

Three-dimensional high dose rate intracavitary image-guided brachytherapy for the treatment of cervical cancer using a hybrid magnetic resonance imaging/computed tomography approach: feasibility and early results

S Beriwal et al. Clin Oncol (R Coll Radiol). 2011 Dec.

Abstract

Aims: To evaluate the feasibility and outcome of image-guided brachytherapy (IGBT) for treating cervical cancer using magnetic resonance imaging (MRI)-based planning for the first fraction followed by computed tomography (CT)-based planning for subsequent fractions.

Materials and methods: Forty-four patients with cervical cancer were treated with three-dimensional high dose rate IGBT. The brachytherapy dose was 5.0-6.0 Gy × five fractions. All but five patients received concurrent weekly cisplatinum at 40 mg/m(2). All patients received external beam radiotherapy (EBRT) with a median dose of 45Gy over 25 fractions. Total doses for the high-risk clinical target volume (HRCTV) and organs at risk, including the rectum, bladder and sigmoid, from EBRT and brachytherapy were summated and normalised to a biologically equivalent dose of 2Gy per fraction (EQD(2)). At 3 months after therapy, any early response was assessed with positron emission tomography (PET)/CT imaging.

Results: The mean D(90) for the HRCTV was 83.3 (3.0) Gy. The mean 2 cm (3) dose to the bladder, rectum and sigmoid colon organs was 79.7 (5.1), 57.5 (4.4) and 66.8 (5.7) Gy, respectively. All but one (2.3%) patient had a complete response. Follow-up PET/CT was carried out in 41 (93.0%) patients, of whom 38 (92.5%) had a complete response. Of the 38 patients with a complete response on PET/CT, two had local recurrences at 6 and 8 months, respectively. Actuarial 2 year local control, disease-specific and overall survival rates were 88, 85 and 86%, respectively.

Conclusion: This is the first report of three-dimensional high dose rate IGBT for the treatment of cervical cancer using a hybrid MRI/CT approach. Early results have shown the feasibility of this approach with excellent local control. Additional studies are needed to assess long-term outcomes of local control and associated morbidities.

PubMed Disclaimer

MeSH terms