Improving reproducibility of VEP recording in rats: electrodes, stimulus source and peak analysis
- PMID: 21909708
- DOI: 10.1007/s10633-011-9288-8
Improving reproducibility of VEP recording in rats: electrodes, stimulus source and peak analysis
Abstract
The aims of this study were to evaluate and improve the reproducibility of visual evoked potential (VEP) measurement in rats and to develop a mini-Ganzfeld stimulator for rat VEP recording. VEPs of Sprague-Dawley rats were recorded on one randomly selected eye on three separate days within a week, and the recordings were repeated three times on the first day to evaluate the intrasession repeatability and intersession reproducibility. The VEPs were recorded with subdermal needle and implanted skull screw electrodes, respectively, to evaluate the effect of electrode configuration on VEP reproducibility. We also designed a mini-Ganzfeld stimulator for rats, which provided better eye isolation than the conventional visual stimuli such as flash strobes and large Ganzfeld systems. The VEP responses from mini-Ganzfeld were compared with PS33-PLUS photic strobe and single light-emitting diode (LED). The latencies of P1, N1, P2, N2, and P3 and the amplitude of each component were measured and analysed. Intrasession and intersession within-subject standard deviations (Sw), coefficient of variation, repeatability (R95) and intraclass correlation coefficient (ICC) were calculated. The VEPs recorded using the implanted skull electrodes showed significantly larger amplitude and higher reproducibility compared to the needle electrodes (P<0.05). The mini-Ganzfeld stimulator showed superior repeatability and reproducibility in VEP recording. The intra/intersession ICCs of latency were 0.85/0.70 for mini-Ganzfeld, 0.72/0.62 for PS33-PLUS and only 0.59/0.42 for single LED. The latencies of the early peaks (N1 and P2) demonstrated better reproducibility than the later waves. The mean intrasession and intersession ICCs were 0.96 and 0.86 for the early peaks. Using a combination of skull screw electrodes, mini-Ganzfeld stimulator and early peak analysis, we achieved a high reproducibility in the rat VEP measurement. The latencies of the early peaks of rat VEPs were more consistent, which may be due to their generation in the primary visual cortex via the retino-geniculate fibres.
Similar articles
-
Semi-invasive and non-invasive recording of visual evoked potentials in mice.Doc Ophthalmol. 2019 Jun;138(3):169-179. doi: 10.1007/s10633-019-09680-z. Epub 2019 Mar 6. Doc Ophthalmol. 2019. PMID: 30840173
-
Normalization of visual evoked potentials using underlying electroencephalogram levels improves amplitude reproducibility in rats.Invest Ophthalmol Vis Sci. 2012 Mar 15;53(3):1473-8. doi: 10.1167/iovs.11-8797. Invest Ophthalmol Vis Sci. 2012. PMID: 22297498
-
A new electrophysiological non-invasive method to assess retinocortical conduction time in the Dark Agouti rat through the simultaneous recording of electroretinogram and visual evoked potential.Doc Ophthalmol. 2020 Jun;140(3):245-255. doi: 10.1007/s10633-019-09741-3. Epub 2019 Dec 12. Doc Ophthalmol. 2020. PMID: 31832898
-
Visually evoked potentials.Handb Clin Neurol. 2019;160:501-522. doi: 10.1016/B978-0-444-64032-1.00034-5. Handb Clin Neurol. 2019. PMID: 31277872 Review.
-
A Comprehensive Review on Methodologies Employed for Visual Evoked Potentials.Scientifica (Cairo). 2016;2016:9852194. doi: 10.1155/2016/9852194. Epub 2016 Feb 29. Scientifica (Cairo). 2016. PMID: 27034907 Free PMC article. Review.
Cited by
-
Visual Evoked Potential Recording in a Rat Model of Experimental Optic Nerve Demyelination.J Vis Exp. 2015 Jul 29;(101):e52934. doi: 10.3791/52934. J Vis Exp. 2015. PMID: 26273963 Free PMC article.
-
Visual evoked potential in RCS rats with Okayama University-type retinal prosthesis (OUReP™) implantation.J Artif Organs. 2017 Jun;20(2):158-165. doi: 10.1007/s10047-016-0943-4. Epub 2017 Feb 8. J Artif Organs. 2017. PMID: 28181076 Free PMC article.
-
Torsion-Induced Traumatic Optic Neuropathy (TITON): A physiologically relevant animal model of traumatic optic neuropathy.PLoS One. 2025 Jan 16;20(1):e0312220. doi: 10.1371/journal.pone.0312220. eCollection 2025. PLoS One. 2025. PMID: 39820583 Free PMC article.
-
Functional and diffusion tensor magnetic resonance imaging of the sheep brain.BMC Vet Res. 2015 Oct 14;11:262. doi: 10.1186/s12917-015-0581-8. BMC Vet Res. 2015. PMID: 26467856 Free PMC article.
-
Non-invasive visual evoked potentials under sevoflurane versus ketamine-xylazine in rats.Heliyon. 2021 Nov 9;7(11):e08360. doi: 10.1016/j.heliyon.2021.e08360. eCollection 2021 Nov. Heliyon. 2021. PMID: 34816047 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources