Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2012 Jan;39(1):57-71.
doi: 10.1007/s00259-011-1938-2. Epub 2011 Sep 20.

Comparison of 18F-dopa PET/CT and 123I-MIBG scintigraphy in stage 3 and 4 neuroblastoma: a pilot study

Affiliations
Comparative Study

Comparison of 18F-dopa PET/CT and 123I-MIBG scintigraphy in stage 3 and 4 neuroblastoma: a pilot study

Arnoldo Piccardo et al. Eur J Nucl Med Mol Imaging. 2012 Jan.

Abstract

Purpose: (18)F-Dopa positron emission tomography (PET)/CT has proved a valuable tool for the assessment of neuroendocrine tumours. So far no data are available on (18)F-dopa utilization in neuroblastoma (NB). Our aim was to evaluate the role of (18)F-dopa PET/CT in NB and compare its diagnostic value with that of (123)I-metaiodobenzylguanidine (MIBG) scintigraphy in patients affected by stage 3-4 NB.

Methods: We prospectively evaluated 28 paired (123)I-MIBG and (18)F-dopa PET/CT scans in 19 patients: 4 at the time of the NB diagnosis and 15 when NB relapse was suspected. For both imaging modalities we performed a scan-based and a lesion-based analysis and calculated sensitivity, specificity and accuracy. The standard of reference was based on clinical, imaging and histological data.

Results: NB localizations were confirmed in 17 of 19 patients. (18)F-Dopa PET/CT and (123)I-MIBG scintigraphy properly detected disease in 16 (94%) and 11 (65%), respectively. On scan-based analysis, (18)F-dopa PET/CT showed a sensitivity and accuracy of 95 and 96%, respectively, while (123)I-MIBG scanning showed a sensitivity and accuracy of 68 and 64%, respectively (p < 0.05). No significant difference in terms of specificity was found. In 9 of 28 paired scans (32%) PET/CT results influenced the patient management. We identified 156 NB localizations, 141 of which were correctly detected by (18)F-dopa PET/CT and 88 by MIBG. On lesion-based analysis, (18)F-dopa PET/CT showed a sensitivity and accuracy of 90% whereas (123)I-MIBG scintigraphy showed a sensitivity and accuracy of 56 and 57%, respectively (p < 0.001). No significant difference in terms of specificity was found.

Conclusion: In our NB population (18)F-dopa PET/CT displayed higher overall accuracy than (123)I-MIBG scintigraphy. Consequently, we suggest (18)F-dopa PET/CT as a new opportunity for NB assessment.

PubMed Disclaimer

References

    1. Med Pediatr Oncol. 2000 Apr;34(4):237-41 - PubMed
    1. Nucl Med Commun. 2002 Jul;23(7):663-72 - PubMed
    1. Br J Radiol. 1997 Jan;70:90-2 - PubMed
    1. Med Pediatr Oncol. 2000 Aug;35(2):153-5 - PubMed
    1. J Nucl Med. 1987 Mar;28(3):308-14 - PubMed

Publication types