Comparative Study
. 2012 Aug;21(6):1065-73.
doi: 10.1007/s11136-011-0018-1. Epub 2011 Sep 23.

Comparing the psychometric properties of the EQ-5D-3L and EQ-5D-5L in cancer patients in Korea

Affiliations
Comparative Study

Comparing the psychometric properties of the EQ-5D-3L and EQ-5D-5L in cancer patients in Korea

Seon Ha Kim et al. Qual Life Res. 2012 Aug.

Abstract

Purpose: This study was conducted to assess the redistribution properties of the EQ-5D-3L when using the EQ-5D-5L and to compare the validity, informativity, and reliability of both EQ-5D-3L and EQ-5D-5L in Korean cancer patients.

Methods: Patients visiting one ambulatory cancer center self-administered the two versions of the EQ-5D and the EORTC QLQ-C30 questionnaire. Redistribution properties in each dimension of EQ-5D were analyzed between EQ-5D-3L and EQ-5D-5L. Informativity was evaluated using the Shannon entropy and ceiling effect. Convergent validity was evaluated by comparing the EQ-VAS, ECOG performance status, and EORTC QLQ-C30 subscales. Reliability was also evaluated in terms of test-retest reliability.

Results: All levels of the EQ-5D-3L substantially partitioned into associated levels of the EQ-5D-5L. The average inconsistency rate of the two versions was 3.5%. Absolute informativity was higher for the EQ-5D-5L than for the EQ-5D-3L, but their informative efficiency tended to be similar. The proportion of 'perfect health' (11111) decreased from 16.8% in the EQ-5D-3L to 9.7% in the EQ-5D-5L. EQ-5D-5L demonstrated similar or higher correlations with the EQ-VAS, ECOG performance status, and EORTC QLQ-C30, than the EQ-5D-3L. The intraclass correlation coefficient of the EQ-5D-5L index was 0.77.

Conclusions: The EQ-5D-5L had greater informativity and lower rate in the ceiling effect than those values of the EQ-5D-3L. The EQ-5D-5L showed good construct validity and reasonable reliability. Therefore, considering these findings, the EQ-5D-5L may be preferable to the EQ-5D-3L.