Mechanical and microarchitectural analyses of cancellous bone through experiment and computer simulation
- PMID: 21947767
- DOI: 10.1007/s11517-011-0833-0
Mechanical and microarchitectural analyses of cancellous bone through experiment and computer simulation
Abstract
The relationship between microarchitecture to the failure mechanism and mechanical properties can be assessed through experimental and computational methods. In this study, both methods were utilised using bovine cadavers. Twenty four samples of cancellous bone were extracted from fresh bovine and the samples were cleaned from excessive marrow. Uniaxial compression testing was performed with displacement control. After mechanical testing, each specimen was ashed in a furnace. Four of the samples were exemplarily scanned using micro-computed tomography (μCT) and three dimensional models of the cancellous bones were reconstructed for finite element simulation. The mechanical properties and the failure modes obtained from numerical simulations were then compared to the experiments. Correlations between microarchitectural parameters to the mechanical properties and failure modes were then made. The Young's modulus correlates well with the bone volume fraction with R² = 0.615 and P value 0.013. Three different types of failure modes of cancellous bone were observed: oblique fracture (21.7%), perpendicular global fracture (47.8%), and scattered localised fracture (30.4%). However, no correlations were found between the failure modes to the morphological parameters. The percentage of error between computer predictions and the actual experimental test was from 6 to 12%. These mechanical properties and information on failure modes can be used for the development of synthetic cancellous bone.
Similar articles
-
Intrinsic mechanical properties of trabecular calcaneus determined by finite-element models using 3D synchrotron microtomography.J Biomech. 2007;40(10):2174-83. doi: 10.1016/j.jbiomech.2006.10.032. Epub 2006 Dec 29. J Biomech. 2007. PMID: 17196599
-
Mechanical properties of glenoid cancellous bone.Clin Biomech (Bristol). 2010 May;25(4):292-8. doi: 10.1016/j.clinbiomech.2009.12.009. Epub 2010 Jan 18. Clin Biomech (Bristol). 2010. PMID: 20080324
-
Finite element models predict cancellous apparent modulus when tissue modulus is scaled from specimen CT-attenuation.J Biomech. 2004 May;37(5):613-21. doi: 10.1016/j.jbiomech.2003.10.002. J Biomech. 2004. PMID: 15046990
-
Implementation and validation of finite element model of skull deformation and failure response during uniaxial compression.J Mech Behav Biomed Mater. 2021 Mar;115:104302. doi: 10.1016/j.jmbbm.2020.104302. Epub 2021 Jan 5. J Mech Behav Biomed Mater. 2021. PMID: 33476873
-
Acoustic Emission in Bone Biomechanics: A Comprehensive Review of Mechanical Properties and Predictive Damage Modeling.Sensors (Basel). 2025 Jan 21;25(3):598. doi: 10.3390/s25030598. Sensors (Basel). 2025. PMID: 39943237 Free PMC article. Review.
Cited by
-
Mathematical modeling of vancomycin release from Poly-L-Lactic Acid-Coated implants.PLoS One. 2024 Nov 1;19(11):e0311521. doi: 10.1371/journal.pone.0311521. eCollection 2024. PLoS One. 2024. PMID: 39485770 Free PMC article.
-
Natural Polymeric Scaffolds in Bone Regeneration.Front Bioeng Biotechnol. 2020 May 21;8:474. doi: 10.3389/fbioe.2020.00474. eCollection 2020. Front Bioeng Biotechnol. 2020. PMID: 32509754 Free PMC article. Review.
-
In vivo evaluation of additively manufactured multi-layered scaffold for the repair of large osteochondral defects.Biodes Manuf. 2022;5(3):481-496. doi: 10.1007/s42242-021-00177-w. Epub 2022 Mar 16. Biodes Manuf. 2022. PMID: 35846348 Free PMC article.
-
Design of novel triply periodic minimal surface (TPMS) bone scaffold with multi-functional pores: lower stress shielding and higher mass transport capacity.Front Bioeng Biotechnol. 2024 Jun 26;12:1401899. doi: 10.3389/fbioe.2024.1401899. eCollection 2024. Front Bioeng Biotechnol. 2024. PMID: 38994122 Free PMC article.
-
Evaluation of a topical herbal agent for the promotion of bone healing.Evid Based Complement Alternat Med. 2015;2015:905270. doi: 10.1155/2015/905270. Epub 2015 Feb 25. Evid Based Complement Alternat Med. 2015. PMID: 25810746 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical