Determination of body water compartments in neonatal foals by use of indicator dilution techniques and multifrequency bioelectrical impedance analysis
- PMID: 21962283
- DOI: 10.2460/ajvr.72.10.1390
Determination of body water compartments in neonatal foals by use of indicator dilution techniques and multifrequency bioelectrical impedance analysis
Abstract
Objective: To determine values for total body water (TBW), extracellular fluid volume (ECFV), intracellular fluid volume (ICFV), and plasma volume (PV) in healthy neonatal (< 24 hours old) foals and to create a multifrequency bioelectrical impedance analysis (MF-BIA) model for use in neonatal foals.
Animals: 7 healthy neonatal foals.
Procedures: Deuterium oxide (0.4 g/kg, IV), sodium bromide (30 mg/kg, IV), and Evans blue dye (1 mg/kg, IV) were administered to each foal. Plasma samples were obtained following an equilibration period, and the TBW, ECFV, ICFV, and PV were calculated for each foal. An MF-BIA model was created by use of morphometric measurements from each foal.
Results: Mean ± SD values were obtained for TBW (0.744 ± 0.024 L/kg), ICFV (0.381 ± 0.018 L/kg), ECFV (0.363 ± 0.014 L/kg), and PV (0.096 ± 0.015 L/kg). The 95% limits of agreement between the MF-BIA and indicator dilution techniques were within ± 2 L for TBW and ECFV.
Conclusions and clinical relevance: Fluid volumes in neonatal foals were found to be substantially larger than fluid volumes in adult horses. Multifrequency bioelectrical impedance analysis may be a useful technique for predicting TBW, ICFV, and ECFV in neonatal foals.
Similar articles
-
Use of multifrequency bioelectrical impedance analysis for estimation of total body water and extracellular and intracellular fluid volumes in horses.Am J Vet Res. 2004 Mar;65(3):320-6. doi: 10.2460/ajvr.2004.65.320. Am J Vet Res. 2004. PMID: 15027680
-
Hydration of exercised standardbred racehorses assessed noninvasively using multi-frequency bioelectrical impedance analysis.Equine Vet J Suppl. 2006 Aug;(36):285-90. doi: 10.1111/j.2042-3306.2006.tb05554.x. Equine Vet J Suppl. 2006. PMID: 17402433
-
Total body water and ECFV measured using bioelectrical impedance analysis and indicator dilution in horses.J Appl Physiol (1985). 2000 Aug;89(2):663-71. doi: 10.1152/jappl.2000.89.2.663. J Appl Physiol (1985). 2000. PMID: 10926652
-
Body fluid volumes measurements by impedance: A review of bioimpedance spectroscopy (BIS) and bioimpedance analysis (BIA) methods.Med Eng Phys. 2008 Dec;30(10):1257-69. doi: 10.1016/j.medengphy.2008.06.009. Epub 2008 Aug 3. Med Eng Phys. 2008. PMID: 18676172 Review.
-
Bioelectrical impedance analysis--part I: review of principles and methods.Clin Nutr. 2004 Oct;23(5):1226-43. doi: 10.1016/j.clnu.2004.06.004. Clin Nutr. 2004. PMID: 15380917 Review.
Cited by
-
Effects of Hypotonic and Isotonic Enteral Electrolyte Solutions Administered in Continuous Flow in Weaned Foals.Front Vet Sci. 2020 May 22;7:280. doi: 10.3389/fvets.2020.00280. eCollection 2020. Front Vet Sci. 2020. PMID: 32596264 Free PMC article.
-
Influence of the Respiratory Cycle on Caudal Vena Cava Diameter Measured by Sonography in Healthy Foals: A Pilot Study.J Vet Intern Med. 2017 Sep;31(5):1556-1562. doi: 10.1111/jvim.14793. Epub 2017 Aug 1. J Vet Intern Med. 2017. PMID: 28766820 Free PMC article.
-
Assessment of body fluids and blood parameters associated with rapid weight change in heavy horses.Can Vet J. 2019 Jul;60(7):721-724. Can Vet J. 2019. PMID: 31281188 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources