Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2012 Apr;39(4):919-26.
doi: 10.1183/09031936.00088711. Epub 2011 Sep 29.

Pulmonary embolism: CT signs and cardiac biomarkers for predicting right ventricular dysfunction

Affiliations
Free article
Clinical Trial

Pulmonary embolism: CT signs and cardiac biomarkers for predicting right ventricular dysfunction

T Henzler et al. Eur Respir J. 2012 Apr.
Free article

Abstract

The aim of this study was to prospectively evaluate the accuracy of quantitative cardiac computed tomography (CT) parameters and two cardiac biomarkers (N-terminal-pro-brain natriuretic peptide (NT-pro-BNP) and troponin I), alone and in combination, for predicting right ventricular dysfunction (RVD) in patients with acute pulmonary embolism. 557 consecutive patients with suspected pulmonary embolism underwent pulmonary CT angiography. Patients with pulmonary embolism also underwent echocardiography and NT-pro-BNP/troponin I serum level measurements. Three different CT measurements were obtained (right ventricular (RV)/left ventricular (LV)(axial), RV/LV(4-CH) and RV/LV(volume)). CT measurements and NT-pro-BNP/troponin I serum levels were correlated with RVD at echocardiography. 77 patients with RVD showed significantly higher RV/LV ratios and NT-pro-BNP/troponin I levels compared to those without RVD (RV/LV(axial) 1.68 ± 0.84 versus 1.00 ± 0.21; RV/LV(4-CH) 1.52 ± 0.45 versus 1.01 ± 0.21; RV/LV(volume) 1.97 ± 0.53 versus 1.07 ± 0.52; serum NT-pro-BNP 6,372 ± 2,319 versus 1,032 ± 1,559 ng · L(-1); troponin I 0.18 ± 0.41 versus 0.06 ± 0.18 g · L(-1)). The area under the curve for the detection of RVD of RV/LV(axial), RV/LV(4-CH), RV/LV(volume), NT-pro-BNP and troponin I were 0.84, 0.87, 0.93, 0.83 and 0.70 respectively. The combination of biomarkers and RV/LV(volume) increased the AUC to 0.95 (RV/LV(volume) with NT-pro-BNP) and 0.93 (RV/LV(volume) with troponin I). RV/LV(volume) is the most accurate CT parameter for identifying patients with RVD. A combination of RV/LV(volume) with NT-pro-BNP or troponin I measurements improves the diagnostic accuracy of either test alone.

PubMed Disclaimer

Publication types

MeSH terms