Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2011 Nov;113(5):1058-63.
doi: 10.1213/ANE.0b013e31822c10cd. Epub 2011 Sep 30.

Pleth variability index to predict fluid responsiveness in colorectal surgery

Affiliations

Pleth variability index to predict fluid responsiveness in colorectal surgery

Julian A Hood et al. Anesth Analg. 2011 Nov.

Abstract

Background: Goal-directed fluid therapy during major abdominal surgery may reduce postoperative morbidity. The Pleth Variability Index (PVI), derived from the pulse oximeter waveform, has been shown to be able to predict fluid responsiveness in a number of surgical circumstances. In the present study, we sought to determine whether PVI could predict fluid responsiveness in low-risk colorectal surgery patients who had fluid therapy guided by esophageal Doppler stroke volume measurements.

Methods: Twenty-five low-risk patients undergoing colorectal resection under general anesthesia were studied. Baseline values for esophageal Doppler stroke volume and PVI taken from finger and ear probes were compared with final values after (a) a 500-mL fluid bolus immediately after induction (steady state) and tracheal intubation before the start of the surgery, and (b) 250-mL boluses given in response to a decrease in stroke volume of 10% during surgery as measured by esophageal Doppler (dynamic). Patients were classified into responders and nonresponders based on a stroke volume increase of >10%.

Results: Baseline PVI at the finger was significantly higher in responders in both steady-state and intraoperative conditions. In steady state, PVI at both finger and earlobe had significant predictive ability of an increase in stroke volume: area under the curve for finger 0.96 (95% confidence interval [CI], 0.88-1.00; P=0.011) and for earlobe 0.98 (95% CI, 0.93-1.00; P=0.008). In dynamic intraoperative conditions, PVI at the finger predicted increases in stroke volume, area under the curve 0.71 (95% CI, 0.57-0.85; P=0.006), but PVI at the earlobe had no predictive value.

Conclusions: PVI measured at the finger may be able to predict fluid responsiveness during surgery in ventilated patients.