Abstract
Myocardial contrast echocardiography has been found to be a safe and useful technique for evaluating relative changes in myocardial perfusion and delineating areas at risk. Although earlier contrast agents required direct delivery into the coronary arteries or aortic root, a new echocardiographic contrast agent, sonicated albumin microspheres (Albunex), has been found to cross the pulmonary circulation in experimental models. To determine the safety and preliminary efficacy of intravenous injections of Albunex in humans, 71 patients at three independent medical institutions underwent two-dimensional echocardiographic examination before, during and after the administration of three intravenous doses of Albunex, ranging from 0.01 to 0.12 ml/kg body weight. All patients provided a complete history and underwent physical and neurologic examination and laboratory and electrocardiographic evaluation before the injections; all evaluations (except for the history) were repeated at 2 h and 3 days after the injections of Albunex. The efficacy of the injections was qualitatively assessed by two independent blinded observers using a grading system of 0 to +3, with 0 indicating an absence of contrast effect and +3 indicating full opacification of the cavities examined. All injections were well tolerated and no serious side effects were noted in any of the patients. Irrespective of dose group, a cavity opacification greater than or equal to +2 was seen in the right ventricle in 212 (88%) of 240 injections and in the left ventricle in 151 (63%) of 240 injections as judged by the independent observers. The degree of ventricular cavity opacification appeared to be dose and concentration related.(ABSTRACT TRUNCATED AT 250 WORDS)
Similar articles
-
Safety and efficacy of a new transpulmonary echo contrast agent in echocardiographic studies in patients.J Am Coll Cardiol. 1993 Oct;22(4):1193-8. doi: 10.1016/0735-1097(93)90437-6. J Am Coll Cardiol. 1993. PMID: 8409060 Clinical Trial.
-
Opacification and border delineation improvement in patients with suboptimal endocardial border definition in routine echocardiography: results of the Phase III Albunex Multicenter Trial.J Am Coll Cardiol. 1993 Nov 1;22(5):1494-500. doi: 10.1016/0735-1097(93)90562-f. J Am Coll Cardiol. 1993. PMID: 8227810 Clinical Trial.
-
Contrast opacification of left ventricular myocardium following intravenous administration of sonicated albumin microspheres.Am Heart J. 1991 Dec;122(6):1660-5. doi: 10.1016/0002-8703(91)90284-o. Am Heart J. 1991. PMID: 1957761
-
Italian Society of Cardiovascular Echography (SIEC) Consensus Conference on the state of the art of contrast echocardiography.Ital Heart J. 2004 Apr;5(4):309-34. Ital Heart J. 2004. PMID: 15185894 Review.
-
Contrast echocardiography: current and future applications.J Am Soc Echocardiogr. 2000 Apr;13(4):331-42. doi: 10.1067/mje.2000.105462. J Am Soc Echocardiogr. 2000. PMID: 10756254 Review.
Cited by
-
A bibliometric analysis of contrast-enhanced ultrasound over the past twenty years.Quant Imaging Med Surg. 2024 Aug 1;14(8):5555-5570. doi: 10.21037/qims-24-480. Epub 2024 Jul 11. Quant Imaging Med Surg. 2024. PMID: 39144012 Free PMC article.
-
Left ventricular opacification after peripheral venous injection of a modified albumin solution.Int J Card Imaging. 1992;8(1):53-61. doi: 10.1007/BF01137566. Int J Card Imaging. 1992. PMID: 1619305
-
From Micro- to Nano-Multifunctional Theranostic Platform: Effective Ultrasound Imaging Is Not Just a Matter of Scale.Mol Imaging. 2018 Jan-Dec;17:1536012118778216. doi: 10.1177/1536012118778216. Mol Imaging. 2018. PMID: 30213222 Free PMC article. Review.
-
Section 7--discussion of the mechanical index and other exposure parameters. American Institute of Ultrasound in Medicine.J Ultrasound Med. 2000 Feb;19(2):143-8, 154-68. doi: 10.7863/jum.2000.19.2.143. J Ultrasound Med. 2000. PMID: 10680619 Free PMC article. Review.
-
Toward a Cognitive Neural Prosthesis Using Focused Ultrasound.Front Neurosci. 2017 Nov 15;11:607. doi: 10.3389/fnins.2017.00607. eCollection 2017. Front Neurosci. 2017. PMID: 29187808 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources