Qualifying the use of RIS data for patient dose by comparison with DICOM header data
- PMID: 21979430
- DOI: 10.1093/rpd/ncr352
Qualifying the use of RIS data for patient dose by comparison with DICOM header data
Abstract
A system was developed in 2008 to calculate patient doses using Radiology Information System (RIS) data and presents these data as a patient dose audit. One of the issues with this system was the quality of user-entered data. It has been shown that Digital Imaging and Communication in Medicine (DICOM) header data can be used to perform dose audits with a high level of data accuracy. This study aims to show that using RIS data for dose audits is not only a viable alternative to using DICOM header data, but that it has advantages. A new system was developed to pull header data from DICOM images easily and was installed on a workstation within a hospital department. Data were recovered for a common set of examinations using both RIS and DICOM header data. The data were compared on a result-by-result basis to check for consistency of common fields between RIS and DICOM, as well as assessing the value of data fields uncommon to both systems. The study shows that whilst RIS is not as accurate as DICOM, it does provide enough accurate data and that it has other advantages over using a DICOM approach. These results suggest that a 'best of both worlds' may be achievable using Modality Performed Procedure Step (MPPS).
Similar articles
-
A generic digital imaging and communications in medicine solution for a bidirectional interface between the modality and the radiology information system.J Digit Imaging. 1999 May;12(2 Suppl 1):93-5. doi: 10.1007/BF03168767. J Digit Imaging. 1999. PMID: 10342178 Free PMC article.
-
Interfacing the radiology information system to the modality: an integrated approach.J Digit Imaging. 1999 May;12(2 Suppl 1):91-2. doi: 10.1007/BF03168766. J Digit Imaging. 1999. PMID: 10342177 Free PMC article.
-
Benefits of the DICOM modality performed procedure step.J Digit Imaging. 2005 Dec;18(4):260-9. doi: 10.1007/s10278-005-6702-3. J Digit Imaging. 2005. PMID: 15988627 Free PMC article.
-
[Patient-centered image and data management in radiation oncology].Strahlenther Onkol. 2009 Jan;185(1):1-7. doi: 10.1007/s00066-009-1857-3. Epub 2009 Feb 18. Strahlenther Onkol. 2009. PMID: 19224141 Review. German.
-
Picture archiving and communication in radiology.Rays. 2003 Jan-Mar;28(1):73-81. Rays. 2003. PMID: 14509181 Review.
Cited by
-
Patient dose management solution directly integrated in the RIS: "Gray Detector" software.J Digit Imaging. 2014 Dec;27(6):786-93. doi: 10.1007/s10278-014-9715-y. J Digit Imaging. 2014. PMID: 24965275 Free PMC article.
-
[Current reporting in radiology : what will happen tomorrow?].Radiologe. 2014 Jan;54(1):45-52. doi: 10.1007/s00117-013-2540-3. Radiologe. 2014. PMID: 24402724 German.
-
A comparison of manually populated radiology information system digital radiographic data with electronic dose management systems.Br J Radiol. 2020 Jul;93(1111):20200055. doi: 10.1259/bjr.20200055. Epub 2020 Jun 2. Br J Radiol. 2020. PMID: 32462887 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical