Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2013 Jan;21(1):82-9.
doi: 10.1007/s00167-011-1693-8. Epub 2011 Oct 9.

Differences in fixation stability between spacer plate and plate fixator following high tibial osteotomy

Affiliations
Comparative Study

Differences in fixation stability between spacer plate and plate fixator following high tibial osteotomy

D Pape et al. Knee Surg Sports Traumatol Arthrosc. 2013 Jan.

Abstract

Purpose: Since in vivo stability following high tibial osteotomy is unknown, surgeons customize the postoperative rehabilitation to the assumed implant stability, leaving us with numerous rehabilitation protocols. The purpose of the study is to quantify the fixation stability of different open-wedge high tibial osteotomy implants. It is hypothesized that the higher fixation stability of a plate fixator justifies early weight bearing.

Methods: In this prospective 30-subject clinical trial, fixation stability was determined over a 2-year period using radiostereometric analysis (RSA). Patients were assigned to two angle-stable osteotomy plates: a spacer plate with 6 postoperative weeks of feather-touch weight bearing versus a plate fixator with 2 postoperative weeks of feather-touch weight bearing.

Results: Postoperative RSA data showed a significant higher lateral translation of the distal tibia and a significantly increased subsidence, varus and internal rotation of the tibial head in the spacer plate compared to the plate fixator group. Weight bearing following spacer plate fixation induced significant micromotion 6 weeks after surgery. Three months after surgery, bone healing was achieved regardless of the used implant.

Conclusions: Early weight bearing is appropriate for plate fixator fixation. The 6-week period of delayed weight bearing following spacer plate fixation is inadequate and should be prolonged presumably up to 8-10 weeks to avoid pseudarthrosis and/or recurrence of varus angulation.

Level of evidence: Level II, diagnostic study--investigating a diagnostic test.

PubMed Disclaimer

References

    1. J Knee Surg. 2008 Jan;21(1):68-74 - PubMed
    1. Knee Surg Sports Traumatol Arthrosc. 2010 Feb;18(2):204-11 - PubMed
    1. J Knee Surg. 2005 Apr;18(2):108-15 - PubMed
    1. JAMA. 2001 Jul 11;286(2):188-95 - PubMed
    1. Knee Surg Sports Traumatol Arthrosc. 2003 May;11(3):132-8 - PubMed

Publication types

MeSH terms

LinkOut - more resources