Thyroid imaging using positron emission tomography--a comparison with ultrasound imaging and conventional scintigraphy in thyrotoxicosis
- PMID: 2198979
- DOI: 10.1259/0007-1285-63-749-325
Thyroid imaging using positron emission tomography--a comparison with ultrasound imaging and conventional scintigraphy in thyrotoxicosis
Abstract
Forty-six comparative studies were performed on 41 patients with hyperthyroidism. Clinically these comprised two groups: those with Graves' disease, and those with multinodular goitre. All patients underwent an ultrasound examination and positron emission tomography (PET) using 124I, then gamma camera pinhole imaging following their 131I therapy administration. Although the 131I pinhole imaging was not performed for diagnostic purposes, there was good correlation (78% agreement) between it and 124I PET in determining relative lobe size. Hence either imaging modality could be used as an indicator of the relative radiation dose delivered to each thyroid lobe at a macroscopic level. In terms of gland morphology the PET images corresponded well to the high resolution ultrasound images (78% agreement), unlike the pinhole images which correlated poorly (only 28% agreement). The results showed that PET imaging gives better anatomical and physiological detail than 131I pinhole imaging. In 77% of cases where the pinhole image showed a uniform distribution of radioisotope, the improved spatial resolution of the PET images revealed non-homogeneous distribution indicating a non-uniform distribution of radiation dose. Since all dosimetry calculations are based on the assumption of uniform distribution of radioiodine, this non-uniformity could possibly have important consequences in the outcome of radioiodine therapy in thyrotoxicosis.
Similar articles
-
Evaluation of dosimetry of radioiodine therapy in benign and malignant thyroid disorders by means of iodine-124 and PET.Eur J Nucl Med Mol Imaging. 2002 Jun;29(6):760-7. doi: 10.1007/s00259-002-0775-8. Epub 2002 Mar 27. Eur J Nucl Med Mol Imaging. 2002. PMID: 12029549 Clinical Trial.
-
Measurement of radiation dose to the thyroid using positron emission tomography.Br J Radiol. 1987 Mar;60(711):245-51. doi: 10.1259/0007-1285-60-711-245. Br J Radiol. 1987. PMID: 3494482
-
Thyroid volume measurement in thyrotoxic patients: comparison between ultrasonography and iodine-124 positron emission tomography.Eur J Nucl Med. 1997 Dec;24(12):1470-8. doi: 10.1007/s002590050176. Eur J Nucl Med. 1997. PMID: 9391181
-
Diagnostic imaging work up in multi-nodular goiter.Minerva Endocrinol. 2010 Sep;35(3):153-9. Minerva Endocrinol. 2010. PMID: 20938418 Review.
-
Imaging of thyrotoxicosis.Am J Med. 2012 Sep;125(9):S1-2. doi: 10.1016/j.amjmed.2012.05.012. Am J Med. 2012. PMID: 22938934 Review.
Cited by
-
Wire chambers revisited.Eur J Nucl Med. 1993 Apr;20(4):348-58. doi: 10.1007/BF00169813. Eur J Nucl Med. 1993. PMID: 8491229 Review.
-
Oncology and nuclear medicine: a developing collaboration.Eur J Nucl Med. 1995 Nov;22(11):1229-31. doi: 10.1007/BF00801604. Eur J Nucl Med. 1995. PMID: 8575468 No abstract available.
-
The diagnostic value of 124I-PET in patients with differentiated thyroid cancer.Eur J Nucl Med Mol Imaging. 2008 May;35(5):958-65. doi: 10.1007/s00259-007-0660-6. Epub 2008 Jan 4. Eur J Nucl Med Mol Imaging. 2008. PMID: 18175115 Free PMC article.
-
Dose-response study on thyrotoxic patients undergoing positron emission tomography and radioiodine therapy.Eur J Nucl Med. 1994 Jun;21(6):531-6. doi: 10.1007/BF00173041. Eur J Nucl Med. 1994. PMID: 8082669
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources