Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2012 Jan;102(1):74-81.
doi: 10.1016/j.radonc.2011.09.008. Epub 2011 Oct 10.

Comparison of three-dimensional versus intensity-modulated radiotherapy techniques to treat breast and axillary level III and supraclavicular nodes in a prone versus supine position

Affiliations
Comparative Study

Comparison of three-dimensional versus intensity-modulated radiotherapy techniques to treat breast and axillary level III and supraclavicular nodes in a prone versus supine position

Rajni A Sethi et al. Radiother Oncol. 2012 Jan.

Abstract

Background and purpose: To determine the optimal method of targeting breast and regional nodes in selected breast cancer patients after axillary dissection, we compared the results of IMRT versus no IMRT, and CT-informed versus clinically-placed fields, in supine and prone positions.

Materials and methods: Twelve consecutive breast cancer patients simulated both prone and supine provided the images for this study. Four techniques were used to target breast, level III axilla, and supraclavicular fossa in either position: a traditional three-field three-dimensional conformal radiotherapy (3DCRT) plan, a four-field 3DCRT plan using a posterior axillary boost field, and two techniques using a CT-informed target volume consisting of an optimized 3DCRT plan (CT-planned 3D) and an intensity-modulated radiotherapy (IMRT) plan. The prescribed dose was 50 Gy in 25 fractions.

Results: CT-planned 3D and IMRT techniques improved nodal PTV coverage. Supine, mean nodal PTV V50 was 50% (3-field), 59% (4-field), 92% (CT-planned 3D), and 94% (IMRT). Prone, V50 was 29% (3-field), 42% (4-field), 97% (CT-planned 3D), and 95% (IMRT). Prone positioning, compared to supine, and IMRT technique, compared to 3D, lowered ipsilateral lung V20.

Conclusions: Traditional 3DCRT plans provide inadequate nodal coverage. Prone IMRT technique resulted in optimal target coverage and reduced ipsilateral lung V20.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources