Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1990 Jun;28(6):1108-13.
doi: 10.1128/jcm.28.6.1108-1113.1990.

Effect of endocervical specimen quality on detection of Chlamydia trachomatis and on the incidence of false-positive results with the Chlamydiazyme method

Affiliations

Effect of endocervical specimen quality on detection of Chlamydia trachomatis and on the incidence of false-positive results with the Chlamydiazyme method

J A Kellogg et al. J Clin Microbiol. 1990 Jun.

Abstract

Duplicate endocervical swabs were collected from 1,675 patients to assess the effects of variations in specimen quality on Chlamydiazyme (Abbott Laboratories) detection of Chlamydia trachomatis and the incidence of false-positive results. One swab (at random) from each patient was tested for C. trachomatis antigen by using the standard Chlamydiazyme procedure. A 200-microliter volume of 0.9% saline was added to the other swab from each patient. After vortexing, 20 microliters was smeared on a slide for Papanicolaou (Pap) staining and the remaining specimen was then tested with the Chlamydiazyme assay. The Chlamydiazyme result was positive for 170 (10.1%) and 165 (9.8%) of the stained and unstained duplicate specimens, respectively (no significant difference). Pap stains on smears from 1,536 (91.7%) of the patients were analyzed, and endocervical and/or metaplastic (E-M) cells were detected in 789 (51.4%) smears. Of these 1,536 stained and analyzed specimens, 150 (9.8%) were Chlamydiazyme positive but only 132 (88.0%) of the positive results were confirmed by repeating the test and using a monoclonal blocking antibody (Abbott). Confirmed Chlamydiazyme-positive results were obtained from only 34 (4.6%) of 747 specimens lacking E-M cells but from 98 (12.4%) of 789 specimens containing the cells (P less than 0.001). Of the 150 initially Chlamydiazyme-positive results obtained with Pap-stained, analyzed specimens, 12 (26.1%) of 46 were falsely positive from specimens lacking E-M cells but only 6 (5.8%) of 104 were falsely positive from specimens containing E-M cells (P less than 0.01). C. trachomatis antigen was detected significantly more frequently and false-positive results were significantly less common from specimens in which E-M cells were detected.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Clin Microbiol. 1989 Jun;27(6):1218-21 - PubMed
    1. Pediatr Infect Dis J. 1989 Jun;8(6):358-60 - PubMed
    1. Diagn Cytopathol. 1988;4(3):224-9 - PubMed
    1. J Clin Microbiol. 1989 Aug;27(8):1863-6 - PubMed
    1. J Clin Microbiol. 1989 Sep;27(9):1934-8 - PubMed

Substances