Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2012 Jun;112(6):2267-76.
doi: 10.1007/s00421-011-2196-5. Epub 2011 Oct 14.

A new incremental test for VO₂max accurate measurement by increasing VO₂max plateau duration, allowing the investigation of its limiting factors

Affiliations

A new incremental test for VO₂max accurate measurement by increasing VO₂max plateau duration, allowing the investigation of its limiting factors

Hélène Petot et al. Eur J Appl Physiol. 2012 Jun.

Abstract

The purpose of this study was to (1) validate a new exercise protocol for accurate measurement of VO(2max) by obtention of a VO(2max) plateau for all subjects fit and unfit (2) test the hypothesis that VO(2max) plateau duration is not correlated with VO(2max) and (3) verify that limiting factors of VO(2max) plateau duration are different from those of VO(2max) amplitude. Therefore, 14 subjects performed two incremental cycling tests: (1) a classical incremental test (CIT) to determine VO(2max), the power at VO(2max) (PVO(2max)) and at the lactate threshold (PLT) (2) a new incremental test (NIT) in which the power was decreased just after the subject reached VO(2max). During both protocols, heart rate, stroke volume, cardiac output, the arterio-venous difference and the oxygen blood saturation were recorded. The results showed that, with the NIT, subject could maintain a long VO(2max) plateau (6 ± 3 min), even those who could not reach VO(2max) plateau at the end of CIT (n = 5). The VO(2max) plateau duration was not correlated with VO(2max) amplitude which was correlated with the power at SV(max) (r = 0.888, p < 0.001). The VO(2max) plateau duration was correlated with the power decrease (W/s) during the VO(2max) plateau (r = -0.72, p = 0.003) but not with cardiac-related factors nor with PVO(2max). In conclusion, these experiments showed that it was possible to get a long VO(2max) plateau at the end of NIT whatever the individual VO(2max) amplitude was. The limiting factor of VO(2max) duration was the power output.

PubMed Disclaimer

References

    1. J Appl Physiol (1985). 1993 Dec;75(6):2586-94 - PubMed
    1. J Appl Physiol. 1955 Jul;8(1):73-80 - PubMed
    1. Med Sci Sports Exerc. 1994 Sep;26(9):1116-21 - PubMed
    1. Med Sci Sports Exerc. 2007 Jul;39(7):1186-92 - PubMed
    1. Eur J Appl Physiol. 2007 Sep;101(2):241-7 - PubMed