Clinical evaluation of small diameter straumann implants in partially edentulous patients: a 5-year retrospective study
- PMID: 21998812
- PMCID: PMC3184735
Clinical evaluation of small diameter straumann implants in partially edentulous patients: a 5-year retrospective study
Abstract
Objective: The aim of the present study was to retrospectively evaluate small-diameter (3.3 mm) Straumann® dental implants placed in the maxilla or the mandible over a period of 5 years in function.
Materials and methods: Twenty-eight partially edentulous patients received a total of 48 implants over a 5-year period. After the standard healing period (3 to 6 months), the implants were restored with single-tooth prostheses or fixed partial dentures. All patients were followed according to a strict maintenance program with regular recalls. The cumulative survival rates of implants were analyzed and prosthetic complications were assessed.
Results: After 5 years of function, one single 10-mm-long implant in the maxillary premolar region was lost because of recurrent peri-implant infection in a female patient. Two single 10-mm-long maxillary implants placed in the posterior region were lost due to body fracture. The cumulative 5-year survival rate of the implants was 93.75 %. The most common prosthetic complication was loosening of the occlusal screw.
Conclusion: Within the limited observation period and the number of patients included in this study, it may be concluded that the use of small-diameter implants appears to be predictable if clinical guidelines are followed and appropriate prosthetic restorations are provided. However, it should be noted that fatigue fracture may occur.
Keywords: Complications; Follow-Up; Partial Fixed Prosthesis; Small Diameter Implants.
References
-
- Polizzi G, Fabbro S, Furri M, Herrmann I, Squarzoni S. Clinical application of narrow Brånemark system implants for single-tooth restorations. Int J Oral Maxillofac Implants. 1999 Jul-Aug;14(4):496–503. - PubMed
-
- Block MS, Delgado A, Fontenot MG. The effect of diameter and length of hydroxylapatite-coated dental implants on ultimate pullout force in dog alveolar bone. J Oral Maxillofac Surg. 1990 Feb;48(2):174–8. - PubMed
-
- Block MS, Assael LA. Interdisciplinary advances implant dentistry. J Oral Maxillofac Surg. 2009 Nov;67(11 Suppl):1. - PubMed
-
- Allum SR, Tomlinson RA, Joshi R. The impact of loads on standard diameter, small diameter and mini implants: a comparative laboratory study. Clin Oral Implants Res. 2008 Jun;19(6):553–9. - PubMed
-
- Ettinger RL, Spivey JD, Han DH, Koorbusch GF. Measurement of the interface between bone and imediate endoosseous implants: a pilot study in dogs. Int J Oral Maxillofac Implants. 1993;8(4):420–7. - PubMed
LinkOut - more resources
Full Text Sources