Results from an Australian and New Zealand audit of left ventricular ejection fraction from gated heart pool scan analysis
- PMID: 22001719
- DOI: 10.1097/MNM.0b013e32834c2f0b
Results from an Australian and New Zealand audit of left ventricular ejection fraction from gated heart pool scan analysis
Abstract
Aim: A voluntary audit was undertaken to compare left ventricular ejection fraction (LVEF) calculations from gated heart pool studies using software packages currently available throughout Australia and New Zealand (ANZ).
Methods: A data set previously developed by a task group of the Institute of Physics and Engineering in Medicine (IPEM) consisting of 12 planar gated studies with LVEF ranging from 17 to 67% was provided to each site with worksheets to record individual technologist's results as well as information about individual department's equipment, software used for calculation of LVEF and experience of the analysers. Data analysis included calculation of an overall mean LVEF and standard deviation (SD) for all patients, which were compared with the mean IPEM LVEF. A comparison among software packages was done to examine differences in mean LVEF.
Results: Results were received from a total of 22 sites using six different software packages, with 187 processed studies included for analysis. Reproducibility of studies 4 and 8 showed good agreement, with an SD of 1.0 EF units (P=0.5290). Good correlation was found between the ANZ mean LVEF and the corresponding IPEM value per patient study, with R=0.98. The ANZ overall mean LVEF was 47%, which was higher that the IPEM mean by 4.9 EF units. The average difference among all software packages was +5.1 EF units.
Conclusion: Differences were found between the IPEM mean and the ANZ mean LVEF. Variability in LVEF values between software packages was demonstrated, with an average of 5.1 EF units. The ANZ overall mean for LVEF was 47.2%, being 4.9 EF units higher than the IPEM value.
Similar articles
-
Electrocardiographically gated blood-pool SPECT and left ventricular function: comparative value of 3 methods for ejection fraction and volume estimation.J Nucl Med. 2001 Jul;42(7):1043-9. J Nucl Med. 2001. PMID: 11438625
-
Investigation of normal ranges for left ventricular ejection fraction in cardiac gated blood pool imaging studies using different processing workstations.Nucl Med Commun. 2008 Feb;29(2):103-9. doi: 10.1097/MNM.0b013e3282f20e45. Nucl Med Commun. 2008. PMID: 18094631
-
Accuracy of ventricular volume and ejection fraction measured by gated myocardial SPECT: comparison of 4 software programs.J Nucl Med. 2001 Oct;42(10):1571-8. J Nucl Med. 2001. PMID: 11585875
-
Reference ranges for LVEF and LV volumes from electrocardiographically gated 82Rb cardiac PET/CT using commercially available software.J Nucl Med. 2010 Jun;51(6):898-905. doi: 10.2967/jnumed.109.073858. Epub 2010 May 19. J Nucl Med. 2010. PMID: 20484424
-
One Health research and training in Australia and New Zealand.Infect Ecol Epidemiol. 2016 Nov 29;6:33799. doi: 10.3402/iee.v6.33799. eCollection 2016. Infect Ecol Epidemiol. 2016. PMID: 27906122 Free PMC article. Review.
Cited by
-
NT-proBNP correlates with LVEF decline in HER2-positive breast cancer patients treated with trastuzumab.Cardiooncology. 2019 May 28;5:4. doi: 10.1186/s40959-019-0039-4. eCollection 2019. Cardiooncology. 2019. PMID: 32154011 Free PMC article.
-
Cardiotoxicity during long-term trastuzumab use in patients with HER2-positive metastatic breast cancer: who needs cardiac monitoring?Breast Cancer Res Treat. 2021 Apr;186(3):851-862. doi: 10.1007/s10549-020-06039-w. Epub 2021 Jan 4. Breast Cancer Res Treat. 2021. PMID: 33394273 Free PMC article.
-
Evaluating the accuracy of planar gated blood pool processing software using simulated patient studies.Heliyon. 2024 Sep 2;10(17):e37299. doi: 10.1016/j.heliyon.2024.e37299. eCollection 2024 Sep 15. Heliyon. 2024. PMID: 39296234 Free PMC article.
-
Cardiac monitoring in HER2-positive patients on trastuzumab treatment: A review and implications for clinical practice.Breast. 2020 Aug;52:33-44. doi: 10.1016/j.breast.2020.04.005. Epub 2020 Apr 16. Breast. 2020. PMID: 32361151 Free PMC article. Review.
-
Comparison of estimates of left ventricular ejection fraction obtained from gated blood pool imaging, different software packages and cameras.Cardiovasc J Afr. 2014 Mar-Apr;25(2):44-9. doi: 10.5830/CVJA-2013-082. Cardiovasc J Afr. 2014. PMID: 24844547 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources