Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2012 Jan;35(1):56-63.
doi: 10.1002/jmri.22801. Epub 2011 Oct 14.

Comparison of 3 Tesla proton MR spectroscopy, MR perfusion and MR diffusion for distinguishing glioma recurrence from posttreatment effects

Affiliations
Comparative Study

Comparison of 3 Tesla proton MR spectroscopy, MR perfusion and MR diffusion for distinguishing glioma recurrence from posttreatment effects

James R Fink et al. J Magn Reson Imaging. 2012 Jan.

Abstract

Purpose: To compare 3 Tesla (3T) multi-voxel and single-voxel proton MR spectroscopy (MRS), dynamic susceptibility contrast perfusion MRI (DSC), and diffusion-weighted MRI (DWI) for distinguishing recurrent glioma from postradiation injury.

Materials and methods: We reviewed all 3T MRS, DSC and DWI studies performed for suspicion of malignant glioma recurrence between October 2006 and December 2008. Maximum Cho/NAA and Cho/Cr peak-area and peak-height ratios were recorded for both multi-voxel and single-voxel MRS. Maximum cerebral blood volume (CBV) and minimum apparent diffusion coefficient (ADC) were normalized to white matter. Histopathology and clinical-radiologic follow-up served as reference standards. Receiver operating characteristic curves for each parameter were compared.

Results: Forty lesions were classified as glioma recurrence (n = 30) or posttreatment effect (n = 10). Diagnostic performance was similar for CBV ratio (AUC = 0.917, P < 0.001), multi-voxel Cho/Cr peak-area (AUC = 0.913, P = 0.002), and multi-voxel Cho/NAA peak-height (AUC = 0.913, P = 0.002), while ADC ratio (AUC = 0.726, P = 0.035) did not appear to perform as well. Single-voxel MRS parameters did not reliably distinguish tumor recurrence from posttreatment effects.

Conclusion: A 3T DSC and multi-voxel MRS Cho/Cr peak-area and Cho/NAA peak-height appear to outperform DWI for distinguishing glioma recurrence from posttreatment effects. Single-voxel MRS parameters do not appear to distinguish glioma recurrence from posttreatment effects reliably, and therefore should not be used in place of multi-voxel MRS.

PubMed Disclaimer

Publication types

LinkOut - more resources