Identification of prolonged phrenic nerve conduction time in the ICU: magnetic versus electrical stimulation

Affiliations
Comparative Study

Identification of prolonged phrenic nerve conduction time in the ICU: magnetic versus electrical stimulation

Alexandre Demoule et al. Intensive Care Med. 2011 Dec.

Abstract

Purpose: Retrospective study of prospectively collected data to assess the reliability of cervical magnetic stimulation (CMS) to detect prolonged phrenic nerve (PN) conduction time at the bedside. Because PN injuries may cause diaphragm dysfunction, their diagnosis is relevant in intensive care units (ICU). This is achieved by studying latency and amplitude of diaphragm response to PN stimulation. Electrical stimulation (ES) is the gold standard, but it is difficult to perform in the ICU. CMS is an easy noninvasive tool to assess PN integrity, but co-activates muscles that could contaminate surface chest electromyographic recordings.

Methods: In a first set of 56 ICU patients with suspected PN injury, presence and latency of compound motor action potentials elicited by CMS and ES were compared. With ES as the reference method, CMS was evaluated as a test designed to indicate presence or absence of PN injury. In eight additional patients, intramuscular diaphragm recordings were compared with surface diaphragm recordings and with the electromyograms of possible contamination sources.

Results: The sensitivity of CMS to diagnose abnormal PN conduction was 0.91, and specificity was 0.84, whereas positive and negative predictive values were 0.81 and 0.92, respectively. Passing-Bablok regression analysis suggested no differences between the two measures. The correlation between PN latency in response to CMS and ES was significant. The "diaphragm surface" and "needle" latencies were close, and were significantly different from those of possibly contaminating muscles. One hemidiaphragm showed likely signal contamination.

Conclusion: CMS provides an easy reliable tool to detect prolonged PN conduction time in the ICU.

PubMed Disclaimer

References

    1. J Thorac Cardiovasc Surg. 1994 Feb;107(2):487-98 - PubMed
    1. Clin Neurophysiol. 2007 Nov;118(11):2383-92 - PubMed
    1. Electromyogr Clin Neurophysiol. 1995 Aug-Sep;35(5):317-20 - PubMed
    1. Arch Phys Med Rehabil. 1972 May;53(5):206-11 - PubMed
    1. Neurology. 2006 Jul 25;67(2):288-92 - PubMed

Publication types

LinkOut - more resources