Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2012 Jan;39(1):102-12.
doi: 10.1007/s00259-011-1956-0. Epub 2011 Oct 18.

Coronary risk factors and myocardial blood flow in patients evaluated for coronary artery disease: a quantitative [15O]H2O PET/CT study

Affiliations

Coronary risk factors and myocardial blood flow in patients evaluated for coronary artery disease: a quantitative [15O]H2O PET/CT study

Ibrahim Danad et al. Eur J Nucl Med Mol Imaging. 2012 Jan.

Abstract

Background: There has been increasing interest in quantitative myocardial blood flow (MBF) imaging over the last years and it is expected to become a routinely used technique in clinical practice. Positron emission tomography (PET) using [(15)O]H(2)O is the established gold standard for quantification of MBF in vivo. A fundamental issue when performing quantitative MBF imaging is to define the limits of MBF in a clinically suitable population. The aims of the present study were to determine the limits of MBF and to determine the relationship among coronary artery disease (CAD) risk factors, gender and MBF in a predominantly symptomatic patient cohort without significant CAD.

Methods: A total of 128 patients (mean age 54 ± 10 years, 50 men) with a low to intermediate pretest likelihood of CAD were referred for noninvasive evaluation of CAD using a hybrid PET/computed tomography (PET/CT) scanner. MBF was quantified with [(15)O]H(2)O at rest and during adenosine-induced hyperaemia. Obstructive CAD was excluded in these patients by means of invasive or CT-based coronary angiography.

Results: Global average baseline MBF values were 0.91 ± 0.34 and 1.09 ± 0.30 ml·min(-1)·g(-1) (range 0.54-2.35 and 0.59-2.75 ml·min(-1)·g(-1)) in men and women, respectively (p < 0.01). However, no gender-dependent difference in baseline MBF was seen following correction for rate-pressure product (0.98 ± 0.45 and 1.09 ± 0.30 ml·min(-1)·g(-1) in men and women, respectively; p = 0.08). Global average hyperaemic MBF values were 3.44 ± 1.20 ml·min(-1)·g(-1) in the whole study population, and 2.90 ± 0.85 and 3.78 ± 1.27 ml·min(-1)·g(-1) (range 1.52-5.22 and 1.72-8.15 ml·min(-1)·g(-1)) in men and women, respectively (p < 0.001). Multivariate analysis identified male gender, age and body mass index as having an independently negative impact on hyperaemic MBF.

Conclusion: Gender, age and body mass index substantially influence reference values and should be corrected for when interpreting hyperaemic MBF values.

PubMed Disclaimer

Figures

Fig. 1
Fig. 1
Flow chart showing criteria for exclusion of obstructive CAD (ICA invasive coronary angiography, FFR fractional flow reserve, CTCA CT coronary angiography, CACS coronary artery calcium score)
Fig. 2
Fig. 2
Frequency distributions of global baseline (a) and hyperaemic (b) MBF in the whole study population (a COV 31%, b COV 35%)
Fig. 3
Fig. 3
Hyperaemic MBF in relation to gender, age and BMI. *p < 0.05

References

    1. Knuuti J, Kajander S, Maki M, Ukkonen H. Quantification of myocardial blood flow will reform the detection of CAD. J Nucl Cardiol. 2009;16(4):497–506. doi: 10.1007/s12350-009-9101-1. - DOI - PubMed
    1. Knaapen P, de Haan S, Hoekstra OS, Halbmeijer R, Appelman YE, Groothuis JG, et al. Cardiac PET-CT: advanced hybrid imaging for the detection of coronary artery disease. Neth Heart J. 2010;18(2):90–98. doi: 10.1007/BF03091744. - DOI - PMC - PubMed
    1. Bengel FM, Higuchi T, Javadi MS, Lautamaki R. Cardiac positron emission tomography. J Am Coll Cardiol. 2009;54(1):1–15. doi: 10.1016/j.jacc.2009.02.065. - DOI - PubMed
    1. Di Carli MF, Hachamovitch R. New technology for noninvasive evaluation of coronary artery disease. Circulation. 2007;115(11):1464–1480. doi: 10.1161/CIRCULATIONAHA.106.629808. - DOI - PubMed
    1. Kajander S, Joutsiniemi E, Saraste M, Pietila M, Ukkonen H, Saraste A, et al. Cardiac positron emission tomography/computed tomography imaging accurately detects anatomically and functionally significant coronary artery disease. Circulation. 2010;122(6):603–613. doi: 10.1161/CIRCULATIONAHA.109.915009. - DOI - PubMed

MeSH terms