The radioactive handkerchief sign. A contamination artifact in I-131 imaging for metastatic thyroid carcinoma
- PMID: 2200627
- DOI: 10.1097/00003072-199007000-00008
The radioactive handkerchief sign. A contamination artifact in I-131 imaging for metastatic thyroid carcinoma
Abstract
False-positive findings suggestive of metastatic functioning thyroid carcinoma have been well documented in I-131 whole-body imaging. These artifacts are often associated with contamination from radioiodine-containing body secretions. Recently, a contaminated handkerchief on an iodine-131 whole-body scan was reported. In the following study, two additional cases involving the sequestration of I-131 contaminated handkerchiefs in patients' pockets are presented, and the literature regarding these false-positive findings is reviewed. Although rare, this "radioactive handkerchief sign" may cause serious misinterpretation of a focal radioiodine accumulation.
Similar articles
-
Unusual patterns of I-131 contamination.Ann Nucl Med. 2004 May;18(3):271-4. doi: 10.1007/BF02985010. Ann Nucl Med. 2004. PMID: 15233290
-
[False positive scintigraphic images in the surveillance of differentiated thyroid cancers].Ann Endocrinol (Paris). 1997;58(5):399-407. Ann Endocrinol (Paris). 1997. PMID: 9685998 Review. French.
-
Nasal secretion of iodine-131.Clin Nucl Med. 1990 Sep;15(9):610-1. doi: 10.1097/00003072-199009000-00004. Clin Nucl Med. 1990. PMID: 2119928
-
Radioiodine concentration by the thymus in differentiated thyroid carcinoma: report of five cases.Arq Bras Endocrinol Metabol. 2009 Oct;53(7):874-9. doi: 10.1590/s0004-27302009000700012. Arq Bras Endocrinol Metabol. 2009. PMID: 19942990
-
False-positive iodine-131 whole-body scan findings in patients with differentiated thyroid carcinoma: report of 11 cases and review of the literature.Ann Endocrinol (Paris). 2013 Jul;74(3):221-30. doi: 10.1016/j.ando.2013.05.007. Epub 2013 Jun 21. Ann Endocrinol (Paris). 2013. PMID: 23796008 Review.
Cited by
-
False positive diagnosis on (131)iodine whole-body scintigraphy of differentiated thyroid cancers.Endocrine. 2016 Sep;53(3):626-35. doi: 10.1007/s12020-015-0750-3. Epub 2015 Oct 26. Endocrine. 2016. PMID: 26499192 Review.
-
Unexpected Uptake by the Gallbladder in Post-Ablative I-131 Scan.Mol Imaging Radionucl Ther. 2015 Jun 5;24(2):85-6. doi: 10.4274/mirt.57441. Mol Imaging Radionucl Ther. 2015. PMID: 26316474 Free PMC article.
-
False-positive uptake on radioiodine whole-body scintigraphy: physiologic and pathologic variants unrelated to thyroid cancer.Am J Nucl Med Mol Imaging. 2012;2(3):362-85. Epub 2012 Jul 10. Am J Nucl Med Mol Imaging. 2012. PMID: 23133823 Free PMC article.
-
Radioiodine Contamination Artifacts and Unusual Patterns of Accumulation in Whole-body I-131 Imaging: A Case Series.Int J Endocrinol Metab. 2014 Jan 1;12(1):e9329. doi: 10.5812/ijem.9329. eCollection 2014 Jan. Int J Endocrinol Metab. 2014. PMID: 24696698 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical