Transapical aortic 'valve-in-valve' procedure for degenerated stented bioprosthesis
- PMID: 22011780
- DOI: 10.1093/ejcts/ezr027
Transapical aortic 'valve-in-valve' procedure for degenerated stented bioprosthesis
Abstract
Standard surgical aortic valve replacement with a biological prosthesis remains the treatment of choice for low- and mid-risk elderly patients (traditionally >65 years of age) suffering from severe symptomatic aortic valve stenosis or insufficiency, and for young patients with formal contraindications to long-lasting anticoagulation. Unfortunately, despite the fact that several technical improvements have noticeably improved the resistance of pericardial and bovine bioprostheses to leaflet calcifications and ruptures, the risk of early valve failure with rapid degeneration still exists, especially for patients under haemodialysis and for patients <60 years of age at the time of surgery. Until now, redo open heart surgery under cardiopulmonary bypass and on cardioplegic arrest was the only available therapeutic option in case of bioprosthesis degeneration, but it carried a higher surgical risk when elderly patients with severe concomitant comorbidities were concerned. Since a few years, the advent of new transcatheter aortic valve procedures has opened new horizons in cardiac surgery and, in particular, the possibility of implanting stented valves within the degenerated stented bioprosthesis, the so-called 'valve-in-valve' (VinV) concept, has become a clinical practice in experienced cardiac centres. The VinV procedure represents a minimally invasive approach dedicated to high-risk redo patients, and published preliminary reports have shown a success rate of 100% with absence of significant valvular leaks, acceptable transvalvular gradients and low complication rate. However, this procedure is not riskless and the most important concerns are about the size mismatch and the right positioning within the degenerated bioprosthesis. In this article, we review the limited available literature about VinV procedures, underline important technical details for the positioning and provide guidelines to prevent valve-prosthesis mismatch comparing the three sizes of the only commercially available transapical device, the Edwards Sapien, with the inner diameter of three of the most commonly used stented bioprostheses.
Similar articles
-
Use of transcatheter heart valves for a valve-in-valve implantation in patients with degenerated aortic bioprosthesis: technical considerations and results.J Thorac Cardiovasc Surg. 2012 Dec;144(6):1372-9; discussion 1379-80. doi: 10.1016/j.jtcvs.2012.07.104. J Thorac Cardiovasc Surg. 2012. PMID: 23140962
-
Transapical off-pump valve-in-valve implantation in patients with degenerated aortic xenografts.Ann Thorac Surg. 2010 Jun;89(6):1934-41. doi: 10.1016/j.athoracsur.2010.02.061. Ann Thorac Surg. 2010. PMID: 20494052
-
Which available transapical transcatheter valve fits into degenerated aortic bioprostheses?Interact Cardiovasc Thorac Surg. 2010 Jul;11(1):83-5. doi: 10.1510/icvts.2010.234625. Epub 2010 Apr 15. Interact Cardiovasc Thorac Surg. 2010. PMID: 20395247 Review.
-
Transcatheter valve-in-valve implantation for degenerated bioprosthetic aortic and mitral valves.Expert Rev Med Devices. 2016 Aug;13(8):749-58. doi: 10.1080/17434440.2016.1207521. Epub 2016 Jul 8. Expert Rev Med Devices. 2016. PMID: 27359372 Review.
-
Valve-in-a-valve concept for transcatheter minimally invasive repeat xenograft implantation.J Am Coll Cardiol. 2007 Jul 3;50(1):56-60. doi: 10.1016/j.jacc.2007.03.030. Epub 2007 Jun 18. J Am Coll Cardiol. 2007. PMID: 17601546
Cited by
-
Transcatheter aortic "valve-in-valve" for degenerated bioprostheses: Choosing the right TAVI valve.Ann Cardiothorac Surg. 2012 Jul;1(2):260-2. doi: 10.3978/j.issn.2225-319X.2012.07.14. Ann Cardiothorac Surg. 2012. PMID: 23977505 Free PMC article.
-
Sutureless Aortic Valve Prosthesis in Redo Procedures: Single-Center Experience.Medicina (Kaunas). 2023 Jun 11;59(6):1126. doi: 10.3390/medicina59061126. Medicina (Kaunas). 2023. PMID: 37374330 Free PMC article.
-
Stroke following transcatheter aortic valve implantation. Is neuroprotection justified?Postepy Kardiol Interwencyjnej. 2013;9(4):376-82. doi: 10.5114/pwki.2013.38868. Epub 2013 Nov 18. Postepy Kardiol Interwencyjnej. 2013. PMID: 24570756 Free PMC article.
-
Choice of Aortic Valve Prosthesis in a Rapidly Aging and Long-Living Society.Ann Thorac Cardiovasc Surg. 2016 Dec 20;22(6):333-339. doi: 10.5761/atcs.oa.16-00104. Epub 2016 Sep 12. Ann Thorac Cardiovasc Surg. 2016. PMID: 27616041 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources