Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2012 May 1;83(1):260-7.
doi: 10.1016/j.ijrobp.2011.06.1959. Epub 2011 Oct 17.

Consolidative involved-node proton therapy for Stage IA-IIIB mediastinal Hodgkin lymphoma: preliminary dosimetric outcomes from a Phase II study

Affiliations
Clinical Trial

Consolidative involved-node proton therapy for Stage IA-IIIB mediastinal Hodgkin lymphoma: preliminary dosimetric outcomes from a Phase II study

Bradford S Hoppe et al. Int J Radiat Oncol Biol Phys. .

Abstract

Purpose: To compare the dose reduction to organs at risk (OARs) with proton therapy (PT) versus three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) in patients with mediastinal Hodgkin lymphoma (HL) enrolled on a Phase II study of involved-node radiotherapy (INRT).

Methods and materials: Between June 2009 and October 2010, 10 patients were enrolled on a University of Florida institutional review board-approved protocol for de novo "classical" Stage IA-IIIB HL with mediastinal (bulky or nonbulky) involvement after chemotherapy. INRT was planned per European Organization for Research and Treatment of Cancer guidelines. Three separate optimized plans were developed for each patient: 3D-CRT, IMRT, and PT. The primary end point was a 50% reduction in the body V4 with PT compared with 3D-CRT or IMRT.

Results: The median relative reduction with PT in the primary end point, body V4, was 51% compared with 3D-CRT (p = 0.0098) and 59% compared with IMRT (p = 0.0020), thus all patients were offered treatment with PT. PT provided the lowest mean dose to the heart, lungs, and breasts for all 10 patients compared with either 3D-CRT or IMRT. The median difference in the OAR mean dose reduction with PT compared with 3D-CRT were 10.4 Gy/CGE for heart; 5.5 Gy/CGE for lung; 0.9 Gy/CGE for breast; 8.3 Gy/CGE for esophagus; and 4.1 Gy/CGE for thyroid. The median differences for mean OAR dose reduction for PT compared with IMRT were 4.3 Gy/CGE for heart, 3.1 Gy/CGE for lung, 1.4 Gy/CGE for breast, 2.8 Gy/CGE for esophagus, and 2.7 Gy/CGE for thyroid.

Conclusions: All 10 patients benefitted from dose reductions to OARs with PT compared with either 3D-CRT or IMRT. It is anticipated that these reductions in dose to OAR will translate into lower rates of late complications, but long-term follow-up on this Phase II INRT study is needed.

PubMed Disclaimer

Publication types

MeSH terms