Abstract
Background: Different patterns of stress shielding may lead to differences in periprosthetic bone preservation around cemented and uncemented hips in the long term?
Questions/purposes: The purpose of this study is to compare the difference in periprosthetic bone density between cemented Charnley total hip and uncemented hydroxyapatite-coated Furlong THAs at a minimum followup of 12 years (mean, 16 years; range, 12-24 years).
Methods: We studied a cohort of 17 patients who had bilateral THAs with a cemented Charnley THA on one side and an uncemented Furlong hydroxyapatite-coated THA on the other side. At a minimum followup of 12 years, Harris and Oxford hip scores were used to determine the function, and dual-energy x-ray absorptiometry was used to quantify bone mineral density adjacent to the prosthesis. The results of the dual-energy x-ray absorptiometry scan for cemented and uncemented hips were analyzed using paired-sample two-tailed t-tests. To compare the Harris hip scores, a nonparametric Wilcoxon test was used.
Results: Bone mineral density was higher on the uncemented Furlong side in Gruen Zones 2, 3, 5, and 6 of the proximal femur and DeLee and Charnley Zone 1 of the acetabulum. In all other zones, there was no difference. Comparison of Harris and Oxford hip scores showed no differences between the two hips.
Conclusion: Bone density is better preserved around the uncemented hydroxyapatite-coated Furlong stem compared with the Charnley cemented stem.
Level of evidence: Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Figures
References
-
- Aldinger PR, Sabo D, Pritsch M, Thomsen M, Mau H, Ewerbeck V, Breusch SJ. Pattern of periprosthetic bone remodeling around stable uncemented tapered hip stems: a prospective 84-month follow-up study and a median 156-month cross-sectional study with DXA. Calcif Tissue Int. 2003;73:115–121. doi: 10.1007/s00223-002-2036-z. - DOI - PubMed
-
- Cohen B, Rushton N. Accuracy of DEXA measurement of bone mineral density after total hip arthroplasty. J Bone Joint Surg Br. 1995;77:479–483. - PubMed
-
- Cohen B, Rushton N. Bone remodelling in the proximal femur after Charnley total hip arthroplasty. J Bone Joint Surg Br. 1995;77:815–819. - PubMed
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Research Materials