Reproducibility of echocardiographic measurements of human fetal left ventricular volumes and ejection fractions using four-dimensional ultrasound with the spatio-temporal image correlation modality
- PMID: 22018832
- DOI: 10.1016/j.ejogrb.2011.09.036
Reproducibility of echocardiographic measurements of human fetal left ventricular volumes and ejection fractions using four-dimensional ultrasound with the spatio-temporal image correlation modality
Abstract
Objectives: To determine the reproducibility, both reliability and agreement, of measurements of fetal left ventricular parameters from volumes obtained by spatio-temporal image correlation (STIC) acquisition applying virtual organ computer-aided analysis (VOCAL) and Simpson's rule (method of discs). Furthermore the success rate of STIC acquisition was determined.
Study design: In 84 pregnancies between 20 and 34 weeks of gestation the fetal heart was scanned using the STIC modality. An optimal four-chamber view in end-diastole and end-systole was obtained. Left ventricular end-diastolic volume, left ventricular end-systolic volume, stroke volume and ejection fraction were determined. For calculations based on Simpson's rule only one plane was traced, whereas for VOCAL six planes were traced. To quantify the reliability intraclass correlation coefficients were calculated for both intra- and inter-observer measurements. Agreement of measurements was evaluated by Bland-Altman plots.
Results: The STIC volumes of 54 women (64%) were excluded from the study because of poor quality, leaving 30 volumes for further analysis. Intraclass correlation coefficients for intra-observer reliability for VOCAL and Simpson were 0.99 and 0.99 for left ventricular end-diastolic volume, 0.95 and 0.92 for left ventricular end-systolic volume, 0.98 and 0.97 for stroke volume, 0.76 and 0.77 for ejection fraction, respectively. Intraclass correlation coefficients for inter-observer reliability for VOCAL and Simpson were 0.97 and 0.86 for left ventricular end-diastolic volume, 0.97 and 0.86 for left ventricular end-systolic volume, 0.95 and 0.81 for stroke volume, 0.68 and 0.63 for ejection fraction, respectively. According to Bland-Altman plots, the mean percentage difference and 95% limits of intra- and inter-observer agreement for left ventricular stroke volume measurements using VOCAL were -0.2 (-25.1, 24.7)% and 2.8 (-34.2, 39.8)%, respectively. For left ventricular stroke volume measured with Simpson versus VOCAL the mean percentage difference and 95% limits of agreement were -1.8 (-22.1, 18.5)%.
Conclusions: 4D STIC enables reproducible measurements of left ventricular volumes. Reliability of the VOCAL mode is not essentially different from the single-plane method used in Simpson's rule. The large percentage of poor quality STIC volumes and the wide limits of inter-observer agreement would create obstacles for the clinical applicability of this technique.
Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Similar articles
-
Fetal cardiac function by three-dimensional ultrasound using 4D-STIC and VOCAL - an update.J Ultrason. 2019 Dec;19(79):287-294. doi: 10.15557/JoU.2019.0043. Epub 2019 Dec 31. J Ultrason. 2019. PMID: 32021711 Free PMC article. Review.
-
Fetal cardiac ventricle volumetry in the second half of gestation assessed by 4D ultrasound using STIC combined with inversion mode.Ultrasound Obstet Gynecol. 2007 Aug;30(2):142-51. doi: 10.1002/uog.4036. Ultrasound Obstet Gynecol. 2007. PMID: 17566143
-
Heart stroke volume, cardiac output, and ejection fraction in 265 normal fetus in the second half of gestation assessed by 4D ultrasound using spatio-temporal image correlation.J Matern Fetal Neonatal Med. 2011 Sep;24(9):1159-67. doi: 10.3109/14767058.2010.545921. Epub 2011 Jan 21. J Matern Fetal Neonatal Med. 2011. PMID: 21250911
-
Heart stroke volume and cardiac output by four-dimensional ultrasound in normal fetuses.Ultrasound Obstet Gynecol. 2008 Aug;32(2):181-7. doi: 10.1002/uog.5374. Ultrasound Obstet Gynecol. 2008. PMID: 18634132
-
Contemporary clinical applications of spatio-temporal image correlation in prenatal diagnosis.Curr Opin Obstet Gynecol. 2011 Apr;23(2):94-102. doi: 10.1097/GCO.0b013e328342ef38. Curr Opin Obstet Gynecol. 2011. PMID: 21178772 Review.
Cited by
-
Fetal cardiac function by three-dimensional ultrasound using 4D-STIC and VOCAL - an update.J Ultrason. 2019 Dec;19(79):287-294. doi: 10.15557/JoU.2019.0043. Epub 2019 Dec 31. J Ultrason. 2019. PMID: 32021711 Free PMC article. Review.
-
The fetal cardiovascular response to increased placental vascular impedance to flow determined with 4-dimensional ultrasound using spatiotemporal image correlation and virtual organ computer-aided analysis.Am J Obstet Gynecol. 2013 Feb;208(2):153.e1-13. doi: 10.1016/j.ajog.2012.11.043. Epub 2012 Dec 7. Am J Obstet Gynecol. 2013. PMID: 23220270 Free PMC article.
-
How to Acquire Cardiac Volumes for Sonographic Examination of the Fetal Heart: Part 1.J Ultrasound Med. 2016 May;35(5):1021-42. doi: 10.7863/ultra.16.01081. Epub 2016 Apr 18. J Ultrasound Med. 2016. PMID: 27091914 Free PMC article.
-
Prospective evaluation of the fetal heart using Fetal Intelligent Navigation Echocardiography (FINE).Ultrasound Obstet Gynecol. 2016 Apr;47(4):450-9. doi: 10.1002/uog.15676. Epub 2016 Mar 10. Ultrasound Obstet Gynecol. 2016. PMID: 26278116 Free PMC article.
-
Fetal cardiac function by mitral and tricuspid annular plane systolic excursion using spatio-temporal image correlation M-mode and left cardiac output in fetuses of pregestational diabetic mothers.Obstet Gynecol Sci. 2021 May;64(3):257-265. doi: 10.5468/ogs.20274. Epub 2021 Jan 27. Obstet Gynecol Sci. 2021. PMID: 33499582 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources