The predictive values of positive and negative test results for human immunodeficiency virus (HIV) antibody are extremely high in laboratories that have good quality control and high performance standards and use licensed FDA-approved enzyme immunoassay (EIA) and Western blot standardized tests. With a carefully designed protocol, the false-positive rate of combined EIA and Western blot has been reported to be as low as 1 in 10(5). When results of HIV confirmatory antibody tests are indeterminate, other tests such as culture and nucleotide probe methods for HIV DNA or RNA may help resolve false-reactive screening EIA tests. Improvements are constantly in progress for HIV laboratory tests with the use of recombinant DNA-derived antigens and synthetic polypeptides. With the use of new-generation synthetic polypeptide antigens, specific assays to identify HIV-1 and HIV-2 have been developed. Recently, assays for the HIV regulatory gene products have been studied for their predictive potential. Antibodies to nef protein, a regulator of HIV-1 replication, may be an early indicator of HIV infection.
Similar articles
-
Comparative evaluation of the Bio-Rad Geenius HIV-1/2 Confirmatory Assay and the Bio-Rad Multispot HIV-1/2 Rapid Test as an alternative differentiation assay for CLSI M53 algorithm-I.J Clin Virol. 2013 Dec;58 Suppl 1:e85-91. doi: 10.1016/j.jcv.2013.08.008. Epub 2013 Aug 28. J Clin Virol. 2013. PMID: 24342484
-
Human immunodeficiency virus (HIV) antigen testing to detect HIV infection in female sex workers in Singapore.Ann Acad Med Singap. 1995 Jul;24(4):534-6. Ann Acad Med Singap. 1995. PMID: 8849183
-
Laboratory diagnosis of human immunodeficiency virus infection.Clin Lab Med. 1989 Sep;9(3):369-92. Clin Lab Med. 1989. PMID: 2676317 Review.
-
Would CLSI M53-A have helped in the diagnosis of HIV in Canada? Results of the performance of Canadian laboratories participating in a recent NLHRS proficiency testing panel containing HIV-1 antigen positive (antibody negative) and HIV-2 samples.J Clin Virol. 2013 Sep;58(1):303-5. doi: 10.1016/j.jcv.2013.04.009. Epub 2013 Jul 26. J Clin Virol. 2013. PMID: 23890809
-
Laboratory methods in the diagnosis and prognostic staging of infection with human immunodeficiency virus type 1.Rev Infect Dis. 1990 Sep-Oct;12(5):912-30. doi: 10.1093/clinids/12.5.912. Rev Infect Dis. 1990. PMID: 2237133 Review.
Cited by
-
Serodeconversion of HIV antibody-positive AIDS patients following treatment with V-1 Immunitor.J Biomed Biotechnol. 2009;2009:934579. doi: 10.1155/2009/934579. Epub 2008 Oct 28. J Biomed Biotechnol. 2009. PMID: 18989372 Free PMC article.
-
Diagnosis of human immunodeficiency virus (HIV) infection: multicenter evaluation of a newly developed anti-HIV 1 and 2 enzyme immunoassay.J Clin Microbiol. 1994 Feb;32(2):403-6. doi: 10.1128/jcm.32.2.403-406.1994. J Clin Microbiol. 1994. PMID: 8150950 Free PMC article. Clinical Trial.
-
Multicenter evaluation of the novel ABN Western blot (immunoblot) system in comparison with an enzyme-linked immunosorbent assay and a different Western blot.J Clin Microbiol. 1992 Mar;30(3):691-7. doi: 10.1128/jcm.30.3.691-697.1992. J Clin Microbiol. 1992. PMID: 1551987 Free PMC article.