Review
. 2011 Oct 27;13(1):63.
doi: 10.1186/1532-429X-13-63.

Magnetic resonance imaging in patients with cardiac pacemakers: era of "MR Conditional" designs

Affiliations
Review

Magnetic resonance imaging in patients with cardiac pacemakers: era of "MR Conditional" designs

Jerold S Shinbane et al. J Cardiovasc Magn Reson. .

Abstract

Advances in cardiac device technology have led to the first generation of magnetic resonance imaging (MRI) conditional devices, providing more diagnostic imaging options for patients with these devices, but also new controversies. Prior studies of pacemakers in patients undergoing MRI procedures have provided groundwork for design improvements. Factors related to magnetic field interactions and transfer of electromagnetic energy led to specific design changes. Ferromagnetic content was minimized. Reed switches were modified. Leads were redesigned to reduce induced currents/heating. Circuitry filters and shielding were implemented to impede or limit the transfer of certain unwanted electromagnetic effects. Prospective multicenter clinical trials to assess the safety and efficacy of the first generation of MR conditional cardiac pacemakers demonstrated no significant alterations in pacing parameters compared to controls. There were no reported complications through the one month visit including no arrhythmias, electrical reset, inhibition of generator output, or adverse sensations. The safe implementation of these new technologies requires an understanding of the well-defined patient and MR system conditions. Although scanning a patient with an MR conditional device following the strictly defined patient and MR system conditions appears straightforward, issues related to patients with pre-existing devices remain complex. Until MR conditional devices are the routine platform for all of these devices, there will still be challenging decisions regarding imaging patients with pre-existing devices where MRI is required to diagnose and manage a potentially life threatening or serious scenario. A range of other devices including ICDs, biventricular devices, and implantable physiologic monitors as well as guidance of medical procedures using MRI technology will require further biomedical device design changes and testing. The development and implementation of cardiac MR conditional devices will continue to require the expertise and collaboration of multiple disciplines and will need to prove safety, effectiveness, and cost effectiveness in patient care.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Intracardiac Electrocardiograms Demonstrating Pacemaker Dependence. Upper Panel: The presenting rhythm is sinus rhythm at 80 beats per minute with ventricular pacing. Middle Panel: Asynchronous dual chamber pacing. Lower Panel: The underlying rhythm is sinus with complete heart block with ventricular pacing at 35 beats per minute. This patient has complete heart block with no ventricular escape at 35 beats per minute.

References

    1. Shinbane JS, Colletti PM, Shellock FG. MR in patients with pacemakers and ICDs: Defining the issues. J Cardiovasc Magn Reson. 2007;9(1):5–13. doi: 10.1080/10976640601117056. - DOI - PubMed
    1. Kalin R, Stanton MS. Current clinical issues for MRI scanning of pacemaker and defibrillator patients. Pacing Clin Electrophysiol. 2005;28(4):326–328. doi: 10.1111/j.1540-8159.2005.50024.x. - DOI - PubMed
    1. Shellock FG, Woods TO, Crues JV. MR labeling information for implants and devices: explanation of terminology. Radiology. 2009;253(1):26–30. doi: 10.1148/radiol.2531091030. - DOI - PubMed
    1. Pavlicek W, Geisinger M, Castle L, Borkowski GP, Meaney TF, Bream BL, Gallagher JH. The effects of nuclear magnetic resonance on patients with cardiac pacemakers. Radiology. 1983;147(1):149–153. - PubMed
    1. Fetter J, Aram G, Holmes DR, Gray JE, Hayes DL. The effects of nuclear magnetic resonance imagers on external and implantable pulse generators. Pacing Clin Electrophysiol. 1984;7(4):720–727. doi: 10.1111/j.1540-8159.1984.tb05602.x. - DOI - PubMed