Comparative Study
. 2011 Dec 9;52(13):9339-44.
doi: 10.1167/iovs.11-8322.

Comparison of autophotomontage software programs in eyes with CMV retinitis

Affiliations
Comparative Study

Comparison of autophotomontage software programs in eyes with CMV retinitis

Jenny Chen et al. Invest Ophthalmol Vis Sci. .

Abstract

Purpose: Automated mosaic software programs are used to stitch together overlapping retinal fundus photographs. The performance of these programs in eyes with retinal diseases has not been independently evaluated. This study compares the quality of the mosaic products of three autophotomontage software programs, using digital fundus photographs of eyes with cytomegalovirus (CMV) retinitis.

Methods: Photographs of 99 eyes with CMV retinitis of 94 patients with HIV were taken at Maharaj Nakorn Chiang Mai Hospital in Chiang Mai, Thailand. Automated mosaic images were created for each of the 99 eyes by three different commercially available programs: IMAGEnet (Topcon, Oakland, NJ), i2k Retina (DualAlign LLC, Clifton Park, NY), and AutoMontage (OIS, Sacramento, CA). Three masked graders ranked each set of mosaics for each eye. The graders also assessed the overall image quality and documented mosaic artifacts in each image.

Results: i2k Retina was ranked as the best program (70%-88%) more often than AutoMontage (10%-33%, P < 0.001) or IMAGEnet (0%-4%, P < 0.001) for creating automontages from digital fundus photographs of eyes with CMV retinitis. Acceptable quality mosaic images were reported most commonly for i2k Retina (93%-94%) and AutoMontage (91%-95%), followed by IMAGEnet (27%-56%, P < 0.001). IMAGEnet had a significantly higher percentage of mosaic errors than did either i2k Retina or AutoMontage (P < 0.001).

Conclusions: In eyes with CMV retinitis, both the i2k Retina and AutoMontage software packages appear to create higher quality mosaics than does IMAGEnet. Automated retinal mosaic imaging may be valuable in diagnosing CMV retinitis and observing disease progression.

PubMed Disclaimer

Figures

Figure 1.
Figure 1.
Percentage of mosaics ranked 1 and 3 and those deemed ungradable. Results for each grader are shown separately, grouped by program (left to right, in each dataset the bars represent graders A, B, and C).
Figure 2.
Figure 2.
Percentage of mosaics with each photographic feature. Results for each grader are shown separately, grouped by program (left to right, in each dataset the bars represent graders A, B, and C).
Figure 3.
Figure 3.
Side-by-side comparisons of mosaics made with the three software programs, showing the completed mosaics, as well as the presence or absence of duplicated blood vessels, relative blurriness of the optic nerve, and overlapping borders from individual images.
Figure 4.
Figure 4.
Side-by-side comparisons of mosaics made with the three software programs, showing the completed mosaics, as well as the presence or absence of missing and misplaced images, linear color distortion, and vessel breaks.

References

    1. Can ACS, Roysam B, Tanenbaum H. A feature-based algorithm for joint, linear estimation of high-order image-to-mosaic transformations: mosaicing the curved human retina. IEEE Trans Pattern Anal Mach Intell. 2002;24(3):412–419
    1. Mahurkar A, Vivino M, Trus B, Kuehl E, Datiles M, Kaiser-Kupfer M. Constructing retinal fundus photomontages. Invest Ophthalmol Vis Sci. 1996;37:1675–1683 - PubMed
    1. Tsai CL, Madore B, Leotta M, et al. Automated retinal image analysis over the Internet. IEEE Trans Inform Technol Biomed. 2008;12(4):480–487 - PubMed
    1. Berger JW, Leventon M, Hata N, Wells W, Kikinis R. Design considerations for a computer-vision-enabled ophthalmic augmented reality environment. Lecture Notes Comput Sci. 1997;1205:399–408
    1. Wiegand TW, Young LH. Cytomegalovirus retinitis. Int Ophthalmol Clin. 2006;46(2):91–110 - PubMed

Publication types