Dynamic contrast-enhanced micro-CT on mice with mammary carcinoma for the assessment of antiangiogenic therapy response
- PMID: 22071777
- DOI: 10.1007/s00330-011-2318-9
Dynamic contrast-enhanced micro-CT on mice with mammary carcinoma for the assessment of antiangiogenic therapy response
Abstract
Objective: To evaluate the potential of in vivo dynamic contrast-enhanced micro-computed tomography (DCE micro-CT) for the assessment of antiangiogenic drug therapy response of mice with mammary carcinoma.
Methods: 20 female mice with implanted MCF7 tumours were split into control group and therapy group treated with a known effective antiangiogenic drug. All mice underwent DCE micro-CT for the 3D analysis of functional parameters (relative blood volume [rBV], vascular permeability [K], area under the time-enhancement curve [AUC]) and morphology. All parameters were determined for total, peripheral and central tumour volumes of interest (VOIs). Immunohistochemistry was performed to characterise tumour vascularisation. 3D dose distributions were determined.
Results: The mean AUCs were significantly lower in therapy with P values of 0.012, 0.007 and 0.023 for total, peripheral and central tumour VOIs. K and rBV showed significant differences for the peripheral (P(per)(K) = 0.032, P(per) (rBV) = 0.029), but not for the total and central tumour VOIs (P(total)(K) = 0.108, P(central)(K) = 0.246, P(total) (rBV) = 0.093, P(central) (rBV) = 0.136). Mean tumour volume was significantly smaller in therapy (P (in vivo) = 0.001, P (ex vivo) = 0.005). Histology revealed greater vascularisation in the controls and central tumour necrosis. Doses ranged from 150 to 300 mGy.
Conclusions: This study indicates the great potential of DCE micro-CT for early in vivo assessment of antiangiogenic drug therapy response.
Key points: Dynamic contrast enhanced micro-CT (computed tomography) is a new experimental laboratory technique. DCE micro-CT allows early in vivo assessment of antiangiogenic drug therapy response. Pharmaceutical drugs can be tested before translation to clinical practice. Both morphological and functional parameters can be obtained using DCE micro-CT. Antiangiogenic effects can be visualised with DCE micro-CT.
Similar articles
-
Dynamic contrast-enhanced micro-computed tomography correlates with 3-dimensional fluorescence ultramicroscopy in antiangiogenic therapy of breast cancer xenografts.Invest Radiol. 2014 Jul;49(7):445-56. doi: 10.1097/RLI.0000000000000038. Invest Radiol. 2014. PMID: 24598441
-
Three-dimensional Dynamic Contrast-enhanced US Imaging for Early Antiangiogenic Treatment Assessment in a Mouse Colon Cancer Model.Radiology. 2015 Nov;277(2):424-34. doi: 10.1148/radiol.2015142824. Epub 2015 May 22. Radiology. 2015. PMID: 26020439 Free PMC article.
-
Dynamic contrast-enhanced computed tomography imaging biomarkers correlated with immunohistochemistry for monitoring the effects of sorafenib on experimental prostate carcinomas.Invest Radiol. 2012 Jan;47(1):49-57. doi: 10.1097/RLI.0b013e3182300fe4. Invest Radiol. 2012. PMID: 21934514
-
Advanced solid tumors treated with cediranib: comparison of dynamic contrast-enhanced MR imaging and CT as markers of vascular activity.Radiology. 2012 Nov;265(2):426-36. doi: 10.1148/radiol.12112565. Epub 2012 Aug 13. Radiology. 2012. PMID: 22891356 Clinical Trial.
-
The promise of dynamic contrast-enhanced imaging in radiation therapy.Semin Radiat Oncol. 2011 Apr;21(2):147-56. doi: 10.1016/j.semradonc.2010.11.001. Semin Radiat Oncol. 2011. PMID: 21356482 Free PMC article. Review.
Cited by
-
Micro-CT imaging of tumor angiogenesis: quantitative measures describing micromorphology and vascularization.Am J Pathol. 2014 Feb;184(2):431-41. doi: 10.1016/j.ajpath.2013.10.014. Epub 2013 Nov 18. Am J Pathol. 2014. PMID: 24262753 Free PMC article.
-
Dynamic contrast-enhanced MR microscopy identifies regions of therapeutic response in a preclinical model of colorectal adenocarcinoma.Med Phys. 2015 May;42(5):2482-8. doi: 10.1118/1.4917525. Med Phys. 2015. PMID: 25979041 Free PMC article.
-
Improving In Vivo High-Resolution CT Imaging of the Tumour Vasculature in Xenograft Mouse Models through Reduction of Motion and Bone-Streak Artefacts.PLoS One. 2015 Jun 5;10(6):e0128537. doi: 10.1371/journal.pone.0128537. eCollection 2015. PLoS One. 2015. PMID: 26046526 Free PMC article.
-
Me2SO perfusion time for whole-organ cryopreservation can be shortened: Results of micro-computed tomography monitoring during Me2SO perfusion of rat hearts.PLoS One. 2020 Sep 2;15(9):e0238519. doi: 10.1371/journal.pone.0238519. eCollection 2020. PLoS One. 2020. PMID: 32877442 Free PMC article.
-
Non-invasive imaging for studying anti-angiogenic therapy effects.Thromb Haemost. 2013 Mar;109(3):375-90. doi: 10.1160/TH12-10-0721. Epub 2013 Feb 14. Thromb Haemost. 2013. PMID: 23407722 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical