The clinical results of arthroscopic transtendinous repair of grade III partial articular-sided supraspinatus tendon tears
- PMID: 22078003
- DOI: 10.1016/j.arthro.2011.08.286
The clinical results of arthroscopic transtendinous repair of grade III partial articular-sided supraspinatus tendon tears
Abstract
Purpose: The purpose of this study was to evaluate the clinical results of arthroscopic transtendinous repair of deep partial articular-sided rotator cuff tears.
Methods: We retrospectively evaluated the results of 53 patients who underwent arthroscopic transtendinous repair for Ellman grade III articular-sided rotator cuff tears (>50% of the thickness of the rotator cuff). The intact bursal side of the cuff was not detached, and all associated pathology was treated. Fifty patients available for follow-up were evaluated with the American Shoulder and Elbow Surgeons (ASES) questionnaire.
Results: American Shoulder and Elbow Surgeons scores improved from a mean of 48.0 to 89.4 (+41.4) (P < .0001). Pain scores on a visual analog scale improved from 5.7 to 1.0 (P < .0001). Ninety-eight percent of patients were satisfied with the results of surgery. Results for the 50 patients available for follow-up were excellent in 32 (64%), good in 6 (12%), fair in 6 (12%), and poor in 6 (12%). Articular-sided rotator cuff tears rarely occurred in isolation but were typically found in association with coexisting pathology suggestive of the tears' etiology. Most common were impingement lesions, seen in 94% of patients, and instability lesions such as labral tears, seen in 30% of patients. Associated procedures included acromioplasty in 47, distal clavicle resection in 29, treatment of biceps pathology in 7, and instability repair in 15. One patient sustained a postoperative pulmonary embolism, which represented the only complication. Tears varied in size from 50% to 90% of the thickness of the cuff insertion. Significant differences were identified in the results of Workers' Compensation patients. Preoperative magnetic resonance imaging and magnetic resonance arthrography were accurate in identifying a partial-thickness rotator cuff tear in less than 40% of cases.
Conclusions: Arthroscopic transtendinous repair of partial articular-sided rotator cuff tears is a safe and effective treatment that allows identification of commonly associated pathology and reliable improvement in pain and function.
Level of evidence: Level IV, therapeutic case series.
Copyright © 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
