Comparative Study
. 2012 Jan;26(1):133-9.
doi: 10.1038/eye.2011.277. Epub 2011 Nov 11.

Retinal nerve fiber layer and macular inner retina measurements by spectral domain optical coherence tomograph in Indian eyes with early glaucoma

Affiliations
Comparative Study

Retinal nerve fiber layer and macular inner retina measurements by spectral domain optical coherence tomograph in Indian eyes with early glaucoma

H L Rao et al. Eye (Lond). 2012 Jan.

Abstract

Purpose: To compare the diagnostic abilities of peripapillary retinal nerve fiber layer (RNFL) and macular inner retina (MIR) measurements by spectral domain optical coherence tomography (SD-OCT) in Indian eyes early glaucoma.

Methods: In an observational, cross-sectional study, 125 eyes of 64 normal subjects and 91 eyes of 59 early glaucoma patients underwent RNFL and MIR imaging with SD-OCT. Glaucomatous eyes had characteristic optic nerve and RNFL abnormalities and correlating visual field defects and a mean deviation of better than or equal to -6 dB on standard automated perimetry. Areas under the receiver operating characteristic curves (AUC), sensitivities at a fixed specificity and likelihood ratios (LRs) were estimated for all RNFL and MIR parameters.

Results: The AUCs for the RNFL parameters ranged from 0.537 for the temporal quadrant thickness to 0.821 for the inferior quadrant RNFL thickness. AUCs for the MIR parameters ranged from 0.603 for the superior minus inferior MIR thickness average to 0.908 for ganglion cell complex focal loss volume (GCC-FLV). AUC for the best MIR parameter (GCC-FLV) was significantly better (P<0.001) than that of the best RNFL parameter (inferior quadrant thickness). The sensitivities of these parameters at high specificity of 95%, however, were comparable (52.7% vs58.2%). Evaluation of the LRs showed that outside normal limits results of most of the RNFL and MIR parameters were associated with large effects on the post-test probability of disease.

Conclusion: MIR parameters with RTVue SD-OCT were as good as the RNFL parameters to detect early glaucoma.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Receiver operating characteristic curves of the best retinal nerve fiber layer (inferior quadrant RNFL thickness) and macular inner retinal (focal loss volume, FLV) parameters.
Figure 2
Figure 2
Receiver operating characteristic curves of the macular inner retinal average thickness and average retinal nerve fiber layer thickness parameters.

References

    1. Medeiros FA, Zangwill LM, Bowd C, Vessani RM, Susanna R, Jr, Weinreb RN. Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography. Am J Ophthalmol. 2005;139:44–55. - PubMed
    1. Wollstein G, Ishikawa H, Wang J, Beaton SA, Schuman JS. Comparison of three optical coherence tomography scanning areas for detection of glaucomatous damage. Am J Ophthalmol. 2005;139:39–43. - PubMed
    1. Hougaard JL, Heijl A, Bengtsson B. Glaucoma detection by Stratus OCT. J Glaucoma. 2007;16:302–306. - PubMed
    1. Parikh RS, Parikh S, Sekhar GC, Kumar RS, Prabakaran S, Babu JG, et al. Diagnostic capability of optical coherence tomography (Stratus OCT 3) in early glaucoma. Ophthalmology. 2007;114:2238–2243. - PubMed
    1. Nouri-Mahdavi K, Nikkhou K, Hoffman DC, Law SK, Caprioli J. Detection of early glaucoma with optical coherence tomography (StratusOCT) J Glaucoma. 2008;17:183–188. - PubMed