[Which hip articulation bearing for which patient? : Tribology of the future]
- PMID: 22083422
- DOI: 10.1007/s00132-011-1849-8
[Which hip articulation bearing for which patient? : Tribology of the future]
Abstract
Replacement of the hip joint has become an exceptionally successful procedure since the inauguration of the low friction principle by Charnley. Aseptic osteolysis and joint dislocation have been addressed by the development of wear-optimized materials and the introduction of larger heads. As an increase in head diameter against polyethylene causes wear increase, larger hard-on-hard bearings were introduced, which exhibit reduced wear and reduced dislocation risk with increasing head diameter. These findings were derived from standard simulator testing, not sufficiently considering the risk of fluid film breakdown under adverse conditions, which can cause a dramatic increase in wear and friction proportional to the head diameter. Such adverse conditions can occur clinically in patients due to several factors and have caused the presently observed unexpected problems with these new designs. Standardized preclinical testing has to be viewed as a minimum requirement but certainly not as a guarantee for the clinical success of new materials and designs even if the testing is adapted to the current patient requirements, which is presently not the case. The future of tribology lies in the prevention of adverse conditions in patients, the improvement and optimized use of proven existing materials and not in the use of new materials.
Similar articles
-
Metal-on-metal hip joint tribology.Proc Inst Mech Eng H. 2006 Feb;220(2):107-18. doi: 10.1243/095441105X69114. Proc Inst Mech Eng H. 2006. PMID: 16669380 Review.
-
High friction moments in large hard-on-hard hip replacement bearings in conditions of poor lubrication.J Orthop Res. 2013 May;31(5):807-13. doi: 10.1002/jor.22255. Epub 2012 Dec 13. J Orthop Res. 2013. PMID: 23239536
-
Wear of 36-mm BIOLOX(R) delta ceramic-on-ceramic bearing in total hip replacements under edge loading conditions.Proc Inst Mech Eng H. 2013 May;227(5):535-42. doi: 10.1177/0954411912474613. Epub 2013 Feb 8. Proc Inst Mech Eng H. 2013. PMID: 23637263
-
Metal-on-metal bearings surfaces: materials, manufacture, design, optimization, and alternatives.Proc Inst Mech Eng H. 2006 Feb;220(2):119-33. doi: 10.1243/095441105X68953. Proc Inst Mech Eng H. 2006. PMID: 16669381 Review.
-
New joints for the Millennium: wear control in total replacement hip joints.Proc Inst Mech Eng H. 2001;215(4):335-58. doi: 10.1243/0954411011535939. Proc Inst Mech Eng H. 2001. PMID: 11521758 Review.
Cited by
-
Feasibility of a Shape-Memory-Alloy-Actuator System for Modular Acetabular Cups.Bioengineering (Basel). 2024 Jan 12;11(1):75. doi: 10.3390/bioengineering11010075. Bioengineering (Basel). 2024. PMID: 38247952 Free PMC article.
-
Manufacturing conditioned roughness and wear of biomedical oxide ceramics for all-ceramic knee implants.Biomed Eng Online. 2013 Aug 29;12:84. doi: 10.1186/1475-925X-12-84. Biomed Eng Online. 2013. PMID: 23988155 Free PMC article.
-
[Endoprostheses in the elderly : Biomaterials, implant selection and fixation technique].Orthopade. 2017 Jan;46(1):4-17. doi: 10.1007/s00132-016-3361-7. Orthopade. 2017. PMID: 27966180 Review. German.
-
[Supramacroparticulate polyethylene in inflammation of synovial-like interface membranes: Characterization and suggested nomenclature].Orthopade. 2016 Mar;45(3):256-64. doi: 10.1007/s00132-015-3194-9. Orthopade. 2016. PMID: 26758878 German.
-
Influence of a Modified Procedure of Joining Ceramic Head and Adapter Sleeve on the Stem Taper in Revision: An Experimental Study.Bioengineering (Basel). 2024 Feb 9;11(2):170. doi: 10.3390/bioengineering11020170. Bioengineering (Basel). 2024. PMID: 38391656 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials