Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1990 Oct;19(4):333-40.
doi: 10.2165/00003088-199019040-00005.

Comparative study of gentamicin release from normal and low viscosity acrylic bone cement

Affiliations
Comparative Study

Comparative study of gentamicin release from normal and low viscosity acrylic bone cement

L Bunetel et al. Clin Pharmacokinet. 1990 Oct.

Abstract

The pharmacokinetics of gentamicin were studied after total hip joint arthroplasties in 2 groups of 10 patients. The prosthesis was performed in the first group with 'Palacos R plus gentamicin' (normal viscosity), manufactured by Schering, and in the second group with 'Cerafix genta R' (low viscosity) manufactured by Ceraver-Osteal. Both cements included similar concentrations of gentamicin. Urine was collected at 12-hour intervals for 15 days after operation, and drainage fluids for 48, 72 or 108 hours. Blood samples were taken 3 and/or 5 hours after prosthesis implantation. In both cases, high concentrations of gentamicin were found in drainage fluids and urine during the early postoperative period. Mean gentamicin excretion curves were calculated by a computer-aided design program (SIAM) for the 2 cements. The release of gentamicin was biphasic in both cases, although the slow elimination phase appeared to be longer for 'Cerafix'. In the first postoperative period, the drug had a better bioavailability during the rapid elimination phase in the case of 'Palacos'. The calculated peak blood concentration was in the same range for both compounds. The conclusion is drawn that, in patients undergoing total hip joint arthroplasties, gentamicin concentrations reach local levels higher than the minimum inhibitory concentrations of most of the likely sensitive pathogens. However, in both cases, as blood concentrations appear to be low, patients will not be protected against systemic infections. Both cements have similar antibacterial properties but the mechanical properties of 'Cerafix' are the better of the two.

PubMed Disclaimer

References

    1. Clin Orthop Relat Res. 1984 Nov;(190):66-74 - PubMed
    1. J Bone Joint Surg Br. 1984 Mar;66(2):175-9 - PubMed
    1. Clin Orthop Relat Res. 1983 Dec;(181):99-106 - PubMed
    1. Clin Pharmacokinet. 1989 Oct;17(4):291-7 - PubMed
    1. Br Med J (Clin Res Ed). 1982 Jul 3;285(6334):10-4 - PubMed

Publication types

LinkOut - more resources