Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2012 Jan;402(3):1217-27.
doi: 10.1007/s00216-011-5548-4. Epub 2011 Nov 23.

A simple assay for the simultaneous determination of rosuvastatin acid, rosuvastatin-5S-lactone, and N-desmethyl rosuvastatin in human plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS)

Affiliations

A simple assay for the simultaneous determination of rosuvastatin acid, rosuvastatin-5S-lactone, and N-desmethyl rosuvastatin in human plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS)

Joyce S Macwan et al. Anal Bioanal Chem. 2012 Jan.

Abstract

A simple and sensitive assay was developed and validated for the simultaneous quantification of rosuvastatin acid (RST), rosuvastatin-5S-lactone (RST-LAC), and N-desmethyl rosuvastatin (DM-RST), in buffered human plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS). All the three analytes and the corresponding deuterium-labeled (d6) internal standards were extracted from 50 μL of buffered human plasma by protein precipitation. The analytes were chromatographically separated using a Zorbax-SB Phenyl column (2.1 mm × 100 mm, 3.5 μm). The mobile phase comprised of a gradient mixture of 0.1% v/v glacial acetic acid in 10% v/v methanol in water (solvent A) and 40% v/v methanol in acetonitrile (solvent B). The analytes were separated at baseline within 6.0 min using a flow rate of 0.35 mL/min. Mass spectrometry detection was carried out in positive electrospray ionization mode. The calibration curves for all three analytes were linear (R ≥ 0.9964, n = 3) over the concentration range of 0.1-100 ng/mL for RST and RST-LAC, and 0.5-100 ng/mL for DM-RST. Mean extraction recoveries ranged within 88.0-106%. Intra- and inter-run mean percent accuracy were within 91.8-111% and percent imprecision was ≤15%. Stability studies revealed that all the analytes were stable in matrix during bench-top (6 h on ice-water slurry), at the end of three successive freeze and thaw cycles and at -80°C for 1 month. The method was successfully applied in a clinical study to determine the concentrations of RST and the lactone metabolite over 12-h post-dose in patients who received a single dose of rosuvastatin.

PubMed Disclaimer

Publication types

LinkOut - more resources