The MiniArc sling for female stress urinary incontinence: clinical results after 1-year follow-up
- PMID: 22109702
- PMCID: PMC3332378
- DOI: 10.1007/s00192-011-1605-y
The MiniArc sling for female stress urinary incontinence: clinical results after 1-year follow-up
Abstract
Introduction and hypothesis: The objective of this study was the assessment of the efficiency of the MiniArc for curing stress urinary incontinence.
Methods: Seventy-seven patients, operated on from March 2008 to November 2009, were evaluated in this study. One-year post-operative data are presented. All patients suffered from predominant stress urinary incontinence. After 1 year, response was 74%. Evaluation was performed using a questionnaire consisting of the EuroQol-5 Dimensions, the Patient Global Impression of Improvement, the Incontinence Impact Questionnaire, the Urinary Distress Inventory, the Prolapse/Urinary Incontinence Sexual Questionnaire, short form, and the Defecation Distress Inventory.
Results: One year after surgery, 68% of the patients stated an improvement in their incontinence status, while only 44% stated to be completely dry.
Conclusion: The 1-year follow-up suggests that the MiniArc is less effective in the treatment of stress urinary incontinence than the TVT.
Comment in
-
Re: the MiniArc sling for female stress urinary incontinence: clinical results after 1-year follow-up.J Urol. 2014 Feb;191(2):418-9. doi: 10.1016/j.juro.2013.10.129. J Urol. 2014. PMID: 24563926 No abstract available.
References
-
- Abrams P, Cardozo L, Fall M, Griffiths D, Rosier P, Ulmsten U, Van KP, Victor A, Wein A. The standardisation of terminology of lower urinary tract function: report from the Standardisation Sub-committee of the International Continence Society. Am J Obstet Gynecol. 2002;187(1):116–126. doi: 10.1067/mob.2002.125704. - DOI - PubMed
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical