Assessment of glomerular filtration rate with dynamic computed tomography in normal Beagle dogs
- PMID: 22122906
- PMCID: PMC3232400
- DOI: 10.4142/jvs.2011.12.4.393
Assessment of glomerular filtration rate with dynamic computed tomography in normal Beagle dogs
Abstract
The objective of our study was to determine individual and global glomerular filtration rates (GFRs) using dynamic renal computed tomography (CT) in Beagle dogs. Twenty-four healthy Beagle dogs were included in the experiment. Anesthesia was induced in all dogs by using propofol and isoflurane prior to CT examination. A single slice of the kidney was sequentially scanned after a bolus intravenous injection of contrast material (iohexol, 1 mL/kg, 300 mgI/mL). Time attenuation curves were created and contrast clearance per unit volume was calculated using a Patlak plot analysis. The CT-GFR was then determined based on the conversion of contrast clearance per unit volume to contrast clearance per body weight. At the renal hilum, CT-GFR values per unit renal volume (mL/min/mL) of the right and left kidneys were 0.69 ± 0.04 and 0.57 ± 0.05, respectively. No significant differences were found between the weight-adjusted CT-GFRs in either kidney at the same renal hilum (p = 0.747). The average global GFR was 4.21 ± 0.25 mL/min/kg and the whole kidney GFR was 33.43 ± 9.20 mL/min. CT-GFR techniques could be a practical way to separately measure GFR in each kidney for clinical and research purposes.
Figures



Similar articles
-
Determination of glomerular filtration rate in dogs using contrast-enhanced computed tomography.Vet Radiol Ultrasound. 2006 Mar-Apr;47(2):127-35. doi: 10.1111/j.1740-8261.2006.00118.x. Vet Radiol Ultrasound. 2006. PMID: 16553143
-
Assessment of glomerular filtration rate measurement in dogs using dynamic contrast CT compared to serum iohexol clearance.Vet Radiol Ultrasound. 2022 Jan;63(1):38-46. doi: 10.1111/vru.13024. Epub 2021 Oct 12. Vet Radiol Ultrasound. 2022. PMID: 34637569
-
Evaluation of glomerular filtration rate by use of dynamic computed tomography and Patlak analysis in clinically normal cats.Am J Vet Res. 2011 Sep;72(9):1276-82. doi: 10.2460/ajvr.72.9.1276. Am J Vet Res. 2011. PMID: 21879988
-
Effects of changes in analytic variables and contrast medium on estimation of glomerular filtration rates by computed tomography in healthy dogs.Am J Vet Res. 2017 Sep;78(9):1049-1055. doi: 10.2460/ajvr.78.9.1049. Am J Vet Res. 2017. PMID: 28836837
-
Determination of glomerular filtration rate in anesthetized pigs by use of three-phase whole-kidney computed tomography and Patlak plot analysis.Am J Vet Res. 2008 Nov;69(11):1455-62. doi: 10.2460/ajvr.69.11.1455. Am J Vet Res. 2008. PMID: 18980427
Cited by
-
320-row CT renal perfusion imaging in patients with aortic dissection: A preliminary study.PLoS One. 2017 Feb 9;12(2):e0171235. doi: 10.1371/journal.pone.0171235. eCollection 2017. PLoS One. 2017. PMID: 28182709 Free PMC article. Clinical Trial.
-
Can distinction between the renal cortex and outer medulla on ultrasonography predict estimated glomerular filtration rate in canine chronic kidney diseases?J Vet Sci. 2020 Jul;21(4):e58. doi: 10.4142/jvs.2020.21.e58. J Vet Sci. 2020. PMID: 32735096 Free PMC article.
-
Cardiovascular-renal axis disorders in the domestic dog and cat: a veterinary consensus statement.J Small Anim Pract. 2015 Sep;56(9):537-52. doi: 10.1111/jsap.12387. J Small Anim Pract. 2015. PMID: 26331869 Free PMC article.
-
Assessment of renal function in patients with unilateral ureteral obstruction using whole-organ perfusion imaging with 320-detector row computed tomography.PLoS One. 2015 Apr 15;10(4):e0122454. doi: 10.1371/journal.pone.0122454. eCollection 2015. PLoS One. 2015. PMID: 25874690 Free PMC article.
-
Contrast enhanced ultrasonography of kidney in conscious and anesthetized beagle dogs.J Vet Med Sci. 2016 Feb;78(2):239-44. doi: 10.1292/jvms.15-0199. Epub 2015 Sep 28. J Vet Med Sci. 2016. PMID: 26412201 Free PMC article.
References
-
- Alexander K, del Castillo JRE, Ybarra N, Morin V, Gauvin D, Authier S, Vinay P, Troncy É. Single-slice dynamic computed tomographic determination of glomerular filtration rate by use of Patlak plot analysis in anesthetized pigs. Am J Vet Res. 2007;68:297–304. - PubMed
-
- Blomley MJ, Dawson P. Review article: the quantification of renal function with enhanced computed tomography. Br J Radiol. 1996;69:989–995. - PubMed
-
- Brown SC, O'Reilly PH. Iohexol clearance for the determination of glomerular filtration rate in clinical practice: evidence for a new gold standard. J Urol. 1991;146:675–679. - PubMed
-
- Chang J, Kim S, Jung J, Lee H, Chang D, Lee Y, Lee I, Yoon J, Choi M. Evaluation of the effects of thiopental, propofol, and etomidate on glomerular filtration rate measured by the use of dynamic computed tomography in dogs. Am J Vet Res. 2011;72:146–151. - PubMed
-
- Cohan RH, Sherman LS, Korobkin M, Bass JC, Francis IR. Renal masses: assessment of corticomedullary-phase and nephrographic phase CT scans. Radiology. 1995;196:445–451. - PubMed