[Evaluation of the automated coagulation analyzer Sysmex(®) CS-2100i (Siemens)]
- PMID: 22123571
- DOI: 10.1684/abc.2011.0624
[Evaluation of the automated coagulation analyzer Sysmex(®) CS-2100i (Siemens)]
Abstract
The Sysmex(®) CS-2100i is a fully automated multiparameter hemostasis analyzer equipped with a photo-optical clot detection unit, a cap-piercing system and a pre-analytical check screens for interfering substances such as bilirubin, lipids and haemolysis (HIL system). It is designed to perform coagulation tests as well as chromogenic and immunologic assays. The aim of the present study was to evaluate its performance. The tests performed were routine coagulation (prothrombin time, activated partial thromboplastin time, fibrinogen, factor VIII and factor V), chromogenic (antithrombin) and immunologic assays (D-Dimer). The intra-assay and inter-assay coefficients of variation (CV) were below 5% for most parameters both in the normal and in the pathological range (exceptions: intra-assay CV = 5.65% for the fibrinogen in the low range of concentrations; and inter-assay CV = 6% for clotting factor). The measured lower limits of linearity for factor VIII and factor V were satisfactory. No sample or reagent carryover was detected in the conditions of the study. Our results demonstrated that using the CS-2100i analyzer, routine coagulation testing can be performed with satisfactory precision.
Similar articles
-
[Evaluation of the automated coagulation analyser Sysmex(®) CS-5100 (Siemens)].Ann Biol Clin (Paris). 2015 Jul-Aug;73(4):413-9. doi: 10.1684/abc.2015.1054. Ann Biol Clin (Paris). 2015. PMID: 26411908 French.
-
Evaluation of the automated coagulation analyzer Sysmex CA-7000.Thromb Res. 2006;117(6):721-9. doi: 10.1016/j.thromres.2005.06.012. Epub 2005 Aug 10. Thromb Res. 2006. PMID: 16098565
-
Evaluation and performance characteristics of the automated coagulation analyzer ACL TOP.Thromb Res. 2007;120(5):733-43. doi: 10.1016/j.thromres.2006.12.002. Epub 2007 Feb 1. Thromb Res. 2007. PMID: 17275069
-
Issues with the assay of factor VIII activity in plasma and factor VIII concentrates.Thromb Haemost. 2000 Dec;84(6):942-8. Thromb Haemost. 2000. PMID: 11154139 Review.
-
Synthetic peptide substrates in hemostatic testing.Crit Rev Clin Lab Sci. 1983;19(2):71-134. doi: 10.3109/10408368309165760. Crit Rev Clin Lab Sci. 1983. PMID: 6373139 Review.
Cited by
-
Heparin resistance in severe thermal injury: A prospective cohort study.Burns Trauma. 2021 Oct 20;9:tkab032. doi: 10.1093/burnst/tkab032. eCollection 2021. Burns Trauma. 2021. PMID: 34692855 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous