Mid-term outcomes after aortic valve replacement with the 17-mm St. Jude Medical Regent valve
- PMID: 22130314
- DOI: 10.1253/circj.cj-11-0733
Mid-term outcomes after aortic valve replacement with the 17-mm St. Jude Medical Regent valve
Abstract
Background: When aortic valve replacement (AVR) is performed in patients with a small aortic annulus, prosthesis-patient mismatch (PPM) is of concern. We investigated the mid-term outcomes of AVR with a 17-mm mechanical prosthesis.
Methods and results: Seventy-eight patients with aortic stenosis underwent AVR with a 17-mm St. Jude Medical Regent prosthesis. Echocardiography was performed preoperatively, at discharge, and at follow-up (mean follow-up, 33 months). Patients were divided into 2 groups: with and without PPM at discharge. Between-group differences in postoperative variables, particularly survival, were analyzed. Overall hospital mortality was 2.6%. Actuarial 1- and 5-year survival rates were 95% and 79%, respectively. Diabetes and renal insufficiency were associated with long-term mortality. Freedom from major adverse valve-related cardiac events at 1 year and 5 years was 97.3% and 93.9%, respectively. Diabetes was shown to be an independent risk factor for major adverse valve-related cardiac events. Echocardiography 13 months after AVR showed a significant increase in mean effective orifice area index, decrease in mean left ventricular-aortic pressure gradient, and decrease in mean left ventricular mass index. PPM at discharge did not influence long-term survival or left ventricular mass regression.
Conclusions: The 17-mm Regent prosthesis provided satisfactory clinical and hemodynamic results. It is a reliable choice for patients with a small aortic annulus.
Similar articles
-
The 17-mm St. Jude Medical Regent valve is a valid option for patients with a small aortic annulus.Ann Thorac Surg. 2009 Jan;87(1):90-4. doi: 10.1016/j.athoracsur.2008.09.051. Ann Thorac Surg. 2009. PMID: 19101276
-
[Mid-long-term clinical results and hemodynamic evaluation of aortic valve replacement with 17 mm St. Jude medical regent valve].Sichuan Da Xue Xue Bao Yi Xue Ban. 2013 Mar;44(2):316-8, 326. Sichuan Da Xue Xue Bao Yi Xue Ban. 2013. PMID: 23745280 Chinese.
-
Hemodynamics and outcomes of aortic valve replacement with a 17- or 19-mm valve.Asian Cardiovasc Thorac Ann. 2010 Oct;18(5):450-5. doi: 10.1177/0218492310381174. Asian Cardiovasc Thorac Ann. 2010. PMID: 20947599
-
Impact of the indexed effective orifice area on mid-term cardiac-related mortality after aortic valve replacement.Heart. 2010 Jun;96(11):865-71. doi: 10.1136/hrt.2009.177220. Epub 2010 Apr 20. Heart. 2010. PMID: 20406767 Review.
-
Is patient-prosthesis mismatch an independent risk factor for early and mid-term overall mortality in adult patients undergoing aortic valve replacement?Interact Cardiovasc Thorac Surg. 2009 Sep;9(3):510-8. doi: 10.1510/icvts.2009.207597. Epub 2009 Jun 4. Interact Cardiovasc Thorac Surg. 2009. PMID: 19497953 Review.
Cited by
-
Impact of Prosthesis-Patient Mismatch After Surgical Aortic Valve Replacement: Systematic Review and Meta-Analysis of Reconstructed Time-to-Event Data of 122 989 Patients With 592 952 Patient-Years.J Am Heart Assoc. 2024 Apr 2;13(7):e033176. doi: 10.1161/JAHA.123.033176. Epub 2024 Mar 27. J Am Heart Assoc. 2024. PMID: 38533939 Free PMC article.
-
Mid-term results of 17-mm St. Jude Medical Regent prosthetic valves in elder patients with small aortic annuli: comparison with 19-mm bioprosthetic valves.J Artif Organs. 2014 Sep;17(3):258-64. doi: 10.1007/s10047-014-0770-4. Epub 2014 May 31. J Artif Organs. 2014. PMID: 24878870
-
Prognosis after surgical replacement with a bioprosthetic aortic valve in patients with severe symptomatic aortic stenosis: systematic review of observational studies.BMJ. 2016 Sep 28;354:i5065. doi: 10.1136/bmj.i5065. BMJ. 2016. PMID: 27683072 Free PMC article.
-
Seventeen-millimeter St. Jude Medical Regent valve in patients with small aortic annulus: dose moderate prosthesis-patient mismatch matter?J Cardiothorac Surg. 2014 Jan 17;9:17. doi: 10.1186/1749-8090-9-17. J Cardiothorac Surg. 2014. PMID: 24438101 Free PMC article.
-
10-year results of On-X bileaflet mechanical heart valve in the aortic position: low target INR regimen in Japanese.Gen Thorac Cardiovasc Surg. 2017 Aug;65(8):435-440. doi: 10.1007/s11748-017-0778-9. Epub 2017 Apr 19. Gen Thorac Cardiovasc Surg. 2017. PMID: 28425027
MeSH terms
LinkOut - more resources
Full Text Sources