Maximum-likelihood estimation: a mathematical model for quantitation in nuclear medicine
- PMID: 2213195
Maximum-likelihood estimation: a mathematical model for quantitation in nuclear medicine
Abstract
In a stimulation study, we investigated the limitations of quantitation in nuclear medicine using a maximum-likelihood (ML) estimation model. We estimated activity, size, and position of a disk-shaped object on a circular, uniform background of unknown activity. The parameter estimates were unbiased, and their standard error was proportional to the square root of the total image counts. The estimates of object activity and size were strongly (negatively) correlated; the position estimates, however, were not correlated with estimates of any other parameters. This implies that a priori knowledge of object location does not improve precision. The minimal model of quantitation tasks should incorporate unknown object activity and size as well as unknown background activity. The ML estimation procedure was used to investigate the trade-off between resolution and sensitivity in gamma camera collimator design. The results implied that for complex tasks such as the multiparameter estimation task investigated here, optimum performance is achieved at a better resolution than that previously found optimal for detection of a well-specified object in a known background.
Comment in
-
Maximum-likelihood estimation: a mathematical model for quantitation in nuclear medicine.J Nucl Med. 1991 May;32(5):898-9. J Nucl Med. 1991. PMID: 2023005 No abstract available.
Similar articles
-
Comparing planar image quality of rotating slat and parallel hole collimation: influence of system modeling.Phys Med Biol. 2008 Apr 7;53(7):1989-2002. doi: 10.1088/0031-9155/53/7/013. Epub 2008 Mar 20. Phys Med Biol. 2008. PMID: 18356576
-
Errors in biased estimators for parametric ultrasonic imaging.IEEE Trans Med Imaging. 1998 Feb;17(1):53-61. doi: 10.1109/42.668694. IEEE Trans Med Imaging. 1998. PMID: 9617907
-
[Meta-analysis of the Italian studies on short-term effects of air pollution].Epidemiol Prev. 2001 Mar-Apr;25(2 Suppl):1-71. Epidemiol Prev. 2001. PMID: 11515188 Italian.
-
Planar gamma camera imaging and quantitation of yttrium-90 bremsstrahlung.J Nucl Med. 1994 Aug;35(8):1381-9. J Nucl Med. 1994. PMID: 8046498
-
Correction of photon attenuation and collimator response for a body-contouring SPECT/CT imaging system.J Nucl Med. 2005 May;46(5):868-77. J Nucl Med. 2005. PMID: 15872362 Clinical Trial.
Cited by
-
Comparison of the scanning linear estimator (SLE) and ROI methods for quantitative SPECT imaging.Phys Med Biol. 2015 Aug 21;60(16):6479-94. doi: 10.1088/0031-9155/60/16/6479. Epub 2015 Aug 6. Phys Med Biol. 2015. PMID: 26247228 Free PMC article.
-
Performance of a high-sensitivity dedicated cardiac SPECT scanner for striatal uptake quantification in the brain based on analysis of projection data.Med Phys. 2013 Apr;40(4):042504. doi: 10.1118/1.4794488. Med Phys. 2013. PMID: 23556920 Free PMC article.
-
Scanning linear estimation: improvements over region of interest (ROI) methods.Phys Med Biol. 2013 Mar 7;58(5):1283-301. doi: 10.1088/0031-9155/58/5/1283. Epub 2013 Feb 6. Phys Med Biol. 2013. PMID: 23384998 Free PMC article.
-
Collimator design for single photon emission tomography.Eur J Nucl Med. 1992;19(2):138-50. doi: 10.1007/BF00184130. Eur J Nucl Med. 1992. PMID: 1563442 Review.
-
Nuclear medicine 2000.Eur J Nucl Med. 1992;19(1):1-5. doi: 10.1007/BF00178300. Eur J Nucl Med. 1992. PMID: 1547801 No abstract available.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical