Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1990 Jun:425:283-99.
doi: 10.1113/jphysiol.1990.sp018103.

Corticospinal volleys evoked by anodal and cathodal stimulation of the human motor cortex

Affiliations

Corticospinal volleys evoked by anodal and cathodal stimulation of the human motor cortex

D Burke et al. J Physiol. 1990 Jun.

Abstract

1. In fifteen neurologically normal subjects, corticospinal volleys evoked by transcranial stimulation of the motor cortex were recorded from the spinal cord using epidural electrodes in the high-thoracic and low-thoracic regions during surgery to correct scoliosis. 2. Anodal stimulation at the vertex produced complex corticospinal volleys that could be recorded at both sites, with multiple waves analogous to the D and I waves documented in animal experiments. These volleys were of higher amplitude when the cathode was 7 cm lateral to the vertex rather than 7 cm anterior. There were no differences in conduction time between the two recording sites for D and I waves, when these waves could be identified at the low-thoracic site. 3. Anodal stimuli of 150 V commonly produced a descending volley containing a single peak at both recording sites. Modest increases in stimulus intensity to 225-375 V produced a peak 0.8 ms in advance of the wave of lowest threshold in thirteen subjects and, in seven subjects, further increases produced an additional peak 1.7 ms in advance of the first-recruited wave. The early peaks increased in size with stimulus intensity, replacing the first-recruited wave. These results suggest that the site of impulse initiation with electrical stimulation of the motor cortex shifts from superficial cortex to deep structures, approximately 5 and 10-11 cm below the cortex. These sites are probably the internal capsule and the cerebral peduncle. 4. With cathode at the vertex and anode over the 'hand area' the response of lowest threshold occurred at the latency of the anodal D wave but could not be recorded at the low-thoracic site, suggesting that it was generated by the anode over the 'hand area'. Slightly higher intensities induced a 'cathodal D wave' and still higher intensities produced late peaks at latencies of anodal I waves. These cathodal D and I waves involved axons innervating lumbar segments. There was no evidence that cathodal stimulation preferentially produced I waves. Cathodal stimulation at the vertex with the anode 7 cm anteriorly produced similar results: D waves were produced at relatively low intensities, but I waves appeared at relatively high stimulus intensities if at all.(ABSTRACT TRUNCATED AT 400 WORDS)

PubMed Disclaimer

Similar articles

Cited by

References

    1. Brain. 1987 Oct;110 ( Pt 5):1191-209 - PubMed
    1. J Physiol. 1990 Jan;420:47-71 - PubMed
    1. Neurosurgery. 1987 Jan;20(1):74-93 - PubMed
    1. J Physiol. 1962 Apr;161:73-90 - PubMed
    1. J Physiol. 1967 Aug;191(3):653-72 - PubMed

Publication types

LinkOut - more resources