10-year clinical outcomes of fixed dental prostheses with zirconia frameworks
- PMID: 22141229
10-year clinical outcomes of fixed dental prostheses with zirconia frameworks
Abstract
Objectives: The aim of this prospective clinical study was to assess the long-term clinical survival rate and the technical and biological complication rates of zirconia-based posterior FDPs.
Materials and methods: Forty-five patients in need of one or more posterior FDPs received 57 three- to five-unit zirconia-based FDPs. The frameworks were fabricated by means of a prototype computer-aided manufacturing (CAM) system (direct ceramic machining, DCM), first processing zirconia in the white stage. The frameworks were veneered with a prototype veneering ceramic.The FDPs were adhesively placed. At baseline, 6 months, and 1,2, 3, 5, 8 and 10 years of function, the FDPs were examined for technical and/or biological complications. Furthermore, the periodontal health of the abutment teeth (test) and untreated control teeth was analyzed. Statistical analysis was performed applying descriptive statistics, Kaplan-Meier survival and multiple mixed effects regression tests.
Results: Twenty-one patients with 26 FDPs were examined at a mean observation time of 10.7 +/- 1.3 years. A total of 16 FDPs were lost to follow-up. Fifteen FDPs had to be replaced due to technical/biological complications; hence, the 10-year survival rate of the FDPs was 67%. Three framework fractures occurred, resulting in a 10-year survival rate for the zirconia frameworks of 91.5%. Chipping/fracture of the veneering ceramic was detected in 16 FDPs over 10 years (complication rate 32%). A significant correlation of the span of the FDPs and the incidence of chipping was observed: 4- and 5-unit FDPs had a 4.9 times higher probability for chipping than 3-unit FDPs. Marginal discrepancy/degradation was found in 90.7% of the FDPs over 10 years. At 11 of the FDPs (complication rate 27%), secondary caries occurred. No difference of the periodontal health was found around test and control teeth.
Conclusion: The zirconia frameworks exhibited very good long-term stability. However, the zirconia-based FDPs frequently exhibited problems such as marginal deficiency or chipping of the veneering ceramic. Both problems may be associated with the prototype status of the system.
Similar articles
-
Clinical prospective evaluation of zirconia-based three-unit posterior fixed dental prostheses: Up-to ten-year results.J Dent. 2016 Apr;47:80-5. doi: 10.1016/j.jdent.2016.01.014. Epub 2016 Feb 1. J Dent. 2016. PMID: 26844399 Clinical Trial.
-
A randomized controlled clinical trial of 3-unit posterior zirconia-ceramic fixed dental prostheses (FDP) with layered or pressed veneering ceramics: 3-year results.J Dent. 2015 Nov;43(11):1365-70. doi: 10.1016/j.jdent.2015.07.013. Epub 2015 Jul 30. J Dent. 2015. PMID: 26234623 Clinical Trial.
-
Three-unit posterior zirconia-ceramic fixed dental prostheses (FDPs) veneered with layered and milled (CAD-on) veneering ceramics: 1-year follow-up of a randomized controlled clinical trial.Quintessence Int. 2015 Nov-Dec;46(10):871-80. doi: 10.3290/j.qi.a34701. Quintessence Int. 2015. PMID: 26345100 Clinical Trial.
-
Current status of zirconia restoration.J Prosthodont Res. 2013 Oct;57(4):236-61. doi: 10.1016/j.jpor.2013.09.001. Epub 2013 Oct 18. J Prosthodont Res. 2013. PMID: 24140561 Review.
-
A systematic review of the survival and complication rates of zirconia-ceramic and metal-ceramic multiple-unit fixed dental prostheses.Clin Oral Implants Res. 2018 Oct;29 Suppl 16:184-198. doi: 10.1111/clr.13277. Clin Oral Implants Res. 2018. PMID: 30328185
Cited by
-
Ten-year survival and chipping rates and clinical quality grading of zirconia-based fixed dental prostheses.Clin Oral Investig. 2018 Nov;22(8):2905-2915. doi: 10.1007/s00784-018-2378-1. Epub 2018 Mar 8. Clin Oral Investig. 2018. PMID: 29520468
-
On the interfacial fracture of porcelain/zirconia and graded zirconia dental structures.Acta Biomater. 2014 Aug;10(8):3756-61. doi: 10.1016/j.actbio.2014.04.016. Epub 2014 Apr 24. Acta Biomater. 2014. PMID: 24769152 Free PMC article.
-
Edge chipping and flexural resistance of monolithic ceramics.Dent Mater. 2013 Dec;29(12):1201-8. doi: 10.1016/j.dental.2013.09.004. Epub 2013 Oct 17. Dent Mater. 2013. PMID: 24139756 Free PMC article.
-
Prospective 5-year clinical evaluation of posterior zirconia fixed dental prostheses veneered with milled lithium disilicate (CADon).J Esthet Restor Dent. 2022 Jan;34(1):136-144. doi: 10.1111/jerd.12877. Epub 2022 Jan 27. J Esthet Restor Dent. 2022. PMID: 35083844 Free PMC article.
-
Do tooth-supported zirconia restorations present more technical failures related to fracture or loss of retention? Systematic review and meta-analysis.Clin Oral Investig. 2022 Aug;26(8):5129-5142. doi: 10.1007/s00784-022-04573-z. Epub 2022 Jun 4. Clin Oral Investig. 2022. PMID: 35660957
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources