Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2011 Nov-Dec;52(6):501-8.

The contegra® valved heterograft conduit for right ventricular outflow tract reconstruction: a reliable solution

Affiliations
  • PMID: 22143013

The contegra® valved heterograft conduit for right ventricular outflow tract reconstruction: a reliable solution

Panagiotis G Sfyridis et al. Hellenic J Cardiol. 2011 Nov-Dec.

Abstract

Introduction: The Contegra® bioprosthetic valved conduit, a glutaraldehyde-preserved valve-containing bovine jugular vein graft (Contegra, Medtronic Inc., Minneapolis MN, USA) introduced for clinical trials in 1998, is used for reconstruction of the right ventricular outflow tract (RVOT), mainly in children. This study evaluates our surgical experience with the Contegra® graft, emphasizing the assessment of conduit durability at mid-term follow up.

Methods: The intermediate results of RVOT reconstruction utilizing the Contegra conduit were retrospectively analyzed in a series of 34 consecutive patients (25 male, 9 female), with a mean age of 10.9 ± 11.2 years (range 0.2-46 years). Included were 14 patients with tetralogy of Fallot (TOF) with pulmonary atresia, 11 with reoperation of previously corrected TOF, 5 with truncus arteriosus, 2 with TOF with absent pulmonary valve, 1 reoperation of previously repaired double outlet right ventricle with pulmonary atresia, and 1 undergoing a Ross procedure. Contegra conduit sizes varied in diameter between 12 and 22 mm (mean 18.3 ± 3.2 mm).

Results: There were no hospital deaths. There was one early conduit replacement as a result of recurrent thrombosis. Four patients developed early thrombus formation in a valve cusp with complete resolution following anticoagulation therapy. At mean follow up of 85 months (range 6-136 months) and median follow up of 95 months, one patient required Contegra graft explantation in another institution (indications unknown). Freedom from reoperation for Contegra grafts was 94% at 11.4 years. Mean transpulmonary pressure gradients remained low (9.6 ± 5.3 mmHg postoperative, 19.6 ± 10.6 mmHg at follow up). Although there was a clear trend towards worsening of conduit valve insufficiency, this was neither statistically significant nor considered clinically so.

Conclusions: In our experience of 34 consecutive operations, the Contegra® valved conduit for RVOT reconstruction seems to be a reliable alternative to homograft conduits, with promising mid-term freedom from structural deterioration and reoperation.

PubMed Disclaimer