Validation of the SenseWear armband in circuit resistance training with different loads
- PMID: 22143845
- DOI: 10.1007/s00421-011-2269-5
Validation of the SenseWear armband in circuit resistance training with different loads
Abstract
The use of the SenseWear™ armband (SWA), an objective monitor of physical activity, is a relatively new device used by researchers to measure energy expenditure. These monitors are practical, relatively inexpensive and easy-to-use. The aim of the present study was to assess the validity of SWAs for the measurement of energy expenditure (EE) in circuit resistance training (CRT) at three different intensities in moderately active, healthy subjects. The study subjects (17 females, 12 males) undertook CRT at 30, 50 and 70% of the 15 repetition maximum for each exercise component wearing an SWA as well as an Oxycon Mobile (OM) portable metabolic system (a gold standard method for measuring EE). The EE rose as exercise intensity increased, but was underestimated by the SWAs. For women, Bland-Altman plots showed a bias of 1.13 ± 1.48 METs and 32.1 ± 34.0 kcal in favour of the OM system, while for men values of 2.33 ± 1.82 METs and 75.8 ± 50.8 kcal were recorded.
Similar articles
-
Monitoring Energy Expenditure Using a Multi-Sensor Device-Applications and Limitations of the SenseWear Armband in Athletic Populations.Front Physiol. 2017 Nov 30;8:983. doi: 10.3389/fphys.2017.00983. eCollection 2017. Front Physiol. 2017. PMID: 29249986 Free PMC article. Review.
-
Accuracy of the SenseWear Armband Mini and the BodyMedia FIT in resistance training.J Sci Med Sport. 2014 Nov;17(6):630-4. doi: 10.1016/j.jsams.2013.08.007. Epub 2013 Sep 13. J Sci Med Sport. 2014. PMID: 24120404 Clinical Trial.
-
Validity of the ActiGraph GT3X+ and BodyMedia SenseWear Armband to estimate energy expenditure during physical activity and sport.J Sci Med Sport. 2018 Mar;21(3):291-295. doi: 10.1016/j.jsams.2017.07.022. Epub 2017 Jul 31. J Sci Med Sport. 2018. PMID: 28797831
-
Validation of the SenseWear Armband at high intensity exercise.Eur J Appl Physiol. 2011 May;111(5):883-7. doi: 10.1007/s00421-010-1695-0. Epub 2010 Oct 24. Eur J Appl Physiol. 2011. PMID: 20972880
-
Study to determine the criterion validity of the SenseWear Armband as a measure of physical activity in people with rheumatoid arthritis.Arthritis Care Res (Hoboken). 2013 Jun;65(6):888-95. doi: 10.1002/acr.21914. Arthritis Care Res (Hoboken). 2013. PMID: 23213019
Cited by
-
Physical Capacity and Energy Expenditure of Cavers.Front Physiol. 2017 Dec 15;8:1067. doi: 10.3389/fphys.2017.01067. eCollection 2017. Front Physiol. 2017. PMID: 29326602 Free PMC article.
-
Validity of SenseWear® Armband v5.2 and v2.2 for estimating energy expenditure.J Sports Sci. 2016 Oct;34(19):1830-8. doi: 10.1080/02640414.2016.1140220. Epub 2016 Feb 8. J Sports Sci. 2016. PMID: 26854829 Free PMC article.
-
Methods to Assess Energy Expenditure of Resistance Exercise: A Systematic Scoping Review.Sports Med. 2024 Sep;54(9):2357-2372. doi: 10.1007/s40279-024-02047-8. Epub 2024 Jun 19. Sports Med. 2024. PMID: 38896201 Free PMC article.
-
Monitoring Energy Expenditure Using a Multi-Sensor Device-Applications and Limitations of the SenseWear Armband in Athletic Populations.Front Physiol. 2017 Nov 30;8:983. doi: 10.3389/fphys.2017.00983. eCollection 2017. Front Physiol. 2017. PMID: 29249986 Free PMC article. Review.
-
Cardiovascular Fitness and Energy Expenditure Response during a Combined Aerobic and Circuit Weight Training Protocol.PLoS One. 2016 Nov 10;11(11):e0164349. doi: 10.1371/journal.pone.0164349. eCollection 2016. PLoS One. 2016. PMID: 27832062 Free PMC article. Clinical Trial.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials
