Implementation of an automated signal detection method in the French pharmacovigilance database: a feasibility study
- PMID: 22143912
- DOI: 10.1007/s00228-011-1178-1
Implementation of an automated signal detection method in the French pharmacovigilance database: a feasibility study
Abstract
Purpose: In France, early detection of adverse effects does not currently involve any automatic signal detection method. The present objective was to assess the feasibility and measure the potential benefit of the incorporation of an automatic signal detection tool (GPS(pH0)) in the French pharmacovigilance system.
Methods: GPS(pH0) was first applied to the data collected from 1 January 2000 to 31 December 2008 and then to the data collected from 1 January 2000 to 31 March 2009. A total of 1,414 original signals were detected. They were shared out for further expertise among 32 centres, i.e. the 31 Regional Pharmacovigilance Centres and the French medicine agency (AFSSAPS) pharmacovigilance department.
Results: The participating centres (n = 28) analysed 1,292 signals in May 2009. Overall, 277 signals whether known or unknown were thus considered worth following up. Half of the other 893 categorised signals were "well-known" (35.7%) and non-interpretable/non-pertinent signals (36.6%); 4% were not categorised because of a lack of time. Analysis of the signals was time-consuming, but the working time estimated by the participants was highly variable (median time: 6 h; minimum: 2 h maximum: 26 h).
Conclusions: The results of this study are in favour of the integration of an automated signal detection tool to complement the current pharmacovigilance activities. The Anatomic Therapeutic Chemical for drug classification poses difficulties in many situations; the international proprietary name might be more efficient. The variability observed in the time needed for analysis suggests that a standardised methodology should be employed. Overall, the findings of this prospective study will contribute to refining the signal management procedure to be implemented in the future.
Similar articles
-
Early detection of pharmacovigilance signals with automated methods based on false discovery rates: a comparative study.Drug Saf. 2012 Jun 1;35(6):495-506. doi: 10.2165/11597180-000000000-00000. Drug Saf. 2012. PMID: 22612853
-
Trends in spontaneous adverse drug reaction reports to the French pharmacovigilance system (1986-2001).Drug Saf. 2005;28(8):731-40. doi: 10.2165/00002018-200528080-00007. Drug Saf. 2005. PMID: 16048358
-
Comparison of two drug safety signals in a pharmacovigilance data mining framework.Stat Methods Med Res. 2016 Apr;25(2):615-29. doi: 10.1177/0962280212462295. Epub 2012 Oct 14. Stat Methods Med Res. 2016. PMID: 23070598
-
[Role and Applicability of Spontaneous Reporting Databases in Medical Big Data].Yakugaku Zasshi. 2021;141(2):165-168. doi: 10.1248/yakushi.20-00196-1. Yakugaku Zasshi. 2021. PMID: 33518634 Review. Japanese.
-
Pharmacovigilance systems and databases in Korea, Japan, and Taiwan.Pharmacoepidemiol Drug Saf. 2011 Dec;20(12):1237-45. doi: 10.1002/pds.2244. Epub 2011 Sep 21. Pharmacoepidemiol Drug Saf. 2011. PMID: 21936017 Review.
Cited by
-
Useful Interplay Between Spontaneous ADR Reports and Electronic Healthcare Records in Signal Detection.Drug Saf. 2015 Dec;38(12):1201-10. doi: 10.1007/s40264-015-0341-5. Drug Saf. 2015. PMID: 26370104 Free PMC article.
References
MeSH terms
LinkOut - more resources
Full Text Sources