Stress analysis of the proximo-medial femur after total hip replacement
- PMID: 2214724
- DOI: 10.1016/0141-5425(90)90020-n
Stress analysis of the proximo-medial femur after total hip replacement
Abstract
Stress-induced bone loss in the proximo-medial femur has been identified as a factor leading to loosening in the artificial hip joint. In an effort to develop a quantitative understanding of the stress distribution that causes bone loss, axial and hoop stresses in the medial calcar of the femur have been determined after total hip replacement, using finite element stress analysis. Stress distributions for a high and a low Young's modulus prosthesis material are compared for both collared and uncollared prosthesis designs. The use of a low-modulus material, and of a collar, are predicted to be advantageous, giving rise to proximo-medial stress patterns similar to those of the normal, intact femur.
Similar articles
-
Role of loads and prosthesis material properties on the mechanics of the proximal femur after total hip arthroplasty.J Orthop Res. 1992 May;10(3):405-22. doi: 10.1002/jor.1100100314. J Orthop Res. 1992. PMID: 1569504
-
[The influence of the elasticity module of the femoral shaft and neck of a total hip prosthesis on the distribution of stress in the femur ].Int Orthop. 1990;14(1):67-73. doi: 10.1007/BF00183368. Int Orthop. 1990. PMID: 2341217 French.
-
The influence of prosthetic stem stiffness and of a calcar collar on stresses in the proximal end of the femur with a cemented femoral component.J Bone Joint Surg Am. 1984 Feb;66(2):280-6. J Bone Joint Surg Am. 1984. PMID: 6693456
-
[Computer stimulation of stress distribution in finite element models of the normal femur and after Weller, Centrament, Parhofer-Mönch type prosthesis implantation].Chir Narzadow Ruchu Ortop Pol. 2000;65(5):519-27. Chir Narzadow Ruchu Ortop Pol. 2000. PMID: 11235082 Review. Polish.
-
A critical analysis of stress shielding evaluation of hip prostheses.Crit Rev Biomed Eng. 1997;25(4-5):409-83. doi: 10.1615/critrevbiomedeng.v25.i4-5.30. Crit Rev Biomed Eng. 1997. PMID: 9505138 Review.
Cited by
-
Comparison of microstructural evolution in Ti-Mo-Zr-Fe and Ti-15Mo biocompatible alloys.J Mater Sci Mater Med. 2005 Jul;16(7):679-85. doi: 10.1007/s10856-005-2540-6. J Mater Sci Mater Med. 2005. PMID: 15965601
-
Cancellous bone from porous Ti6Al4V by multiple coating technique.J Mater Sci Mater Med. 2006 Feb;17(2):179-85. doi: 10.1007/s10856-006-6822-4. J Mater Sci Mater Med. 2006. PMID: 16502251
-
Structure and properties of Titanium-25 Niobium-x iron alloys.J Mater Sci Mater Med. 2002 Jul;13(7):695-700. doi: 10.1023/a:1015798011434. J Mater Sci Mater Med. 2002. PMID: 15348579
-
Large diameter femoral heads impose significant alterations on the strains developed on femoral component and bone: a finite element analysis.Open Orthop J. 2011;5:229-38. doi: 10.2174/1874325001105010229. Epub 2011 Jul 19. Open Orthop J. 2011. PMID: 21792381 Free PMC article.