The low attenuation area on dual-energy perfusion CT: correlation with the pulmonary function tests and quantitative CT measurements
- PMID: 22153984
- DOI: 10.1016/j.ejrad.2011.11.006
The low attenuation area on dual-energy perfusion CT: correlation with the pulmonary function tests and quantitative CT measurements
Abstract
Purpose: To retrospectively investigate the distribution of the low attenuation area (LAA) on dual energy perfusion CT (DEpCT) in comparison with the results of pulmonary function tests (PFTs) and quantitative CT measurements.
Materials and methods: Twenty-eight patients (15 male and 13 female; mean age: 62.21 years) underwent DEpCT and PFTs within a 1-month interval. The ranges of the LAA on DEpCT were classified into six groups with attenuation values of 0-3, 0-5, 0-8, 0-10, 0-13 and 0-15 HU and the ratios of LAA in each group were compared with the percentage of forced expiratory volume in the 1st second (%FEV(1.0)), FEV(1.0)/forced vital capacity (FEV(1.0)/FVC) and the relative area of the lung with attenuation coefficients lower than -950 HU (RA(-950)).
Results: The LAAs on the DEpCT images were significantly correlated with the RA(-950), %FEV(1.0) and FEV(1.0)/FVC, and the regression analysis showed that the best values of LAA on DEpCT were 0-10 HU with RA(-950) (r=0.63), 0-8 HU with %FEV(1.0) (r=-0.52) and 0-8HU with FEV(1.0)/FVC (r=-0.61) per patient.
Conclusion: The iodine disturbance on DEpCT had a moderate correlation with the results of the PFTs and RA(-950), but further examination would be needed for evaluation of iodine distribution.
Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Similar articles
-
The effect of the section thickness used for 2- and 3-dimensional quantification of dual-energy perfusion computed tomography.J Comput Assist Tomogr. 2014 Nov-Dec;38(6):979-84. doi: 10.1097/RCT.0000000000000148. J Comput Assist Tomogr. 2014. PMID: 25229200
-
Quantitative CT in chronic obstructive pulmonary disease: inspiratory and expiratory assessment.AJR Am J Roentgenol. 2009 Jan;192(1):267-72. doi: 10.2214/AJR.07.3953. AJR Am J Roentgenol. 2009. PMID: 19098209
-
Prediction of postoperative lung function in patients undergoing lung resection: dual-energy perfusion computed tomography versus perfusion scintigraphy.Invest Radiol. 2013 Aug;48(8):622-7. doi: 10.1097/RLI.0b013e318289fa55. Invest Radiol. 2013. PMID: 23538887
-
Thoracic applications of dual energy.Semin Respir Crit Care Med. 2014 Feb;35(1):64-73. doi: 10.1055/s-0033-1363452. Epub 2014 Jan 30. Semin Respir Crit Care Med. 2014. PMID: 24481760 Review.
-
Dual-energy lung perfusion and ventilation CT in children.Pediatr Radiol. 2013 Mar;43(3):298-307. doi: 10.1007/s00247-012-2465-4. Epub 2013 Feb 16. Pediatr Radiol. 2013. PMID: 23417255 Review.
Cited by
-
Histogram-pattern analysis of the lung perfused blood volume for assessment of pulmonary thromboembolism.Diagn Interv Radiol. 2018 May-Jun;24(3):139-145. doi: 10.5152/dir.2018.17311. Diagn Interv Radiol. 2018. PMID: 29770766 Free PMC article.
-
Dual-energy perfusion CT of non-diseased lung segments using dual-source CT: correlation with perfusion SPECT.Jpn J Radiol. 2013 Feb;31(2):99-104. doi: 10.1007/s11604-012-0153-9. Epub 2012 Oct 19. Jpn J Radiol. 2013. PMID: 23081761
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical