Agreement assessment of tigecycline susceptibilities determined by the disk diffusion and broth microdilution methods among commonly encountered resistant bacterial isolates: results from the Tigecycline In Vitro Surveillance in Taiwan (TIST) study, 2008 to 2010
- PMID: 22155819
- PMCID: PMC3294924
- DOI: 10.1128/AAC.05879-11
Agreement assessment of tigecycline susceptibilities determined by the disk diffusion and broth microdilution methods among commonly encountered resistant bacterial isolates: results from the Tigecycline In Vitro Surveillance in Taiwan (TIST) study, 2008 to 2010
Abstract
The Tigecycline In Vitro Surveillance in Taiwan (TIST) study, initiated in 2006, is a nationwide surveillance program designed to longitudinally monitor the in vitro activity of tigecycline against commonly encountered drug-resistant bacteria. This study compared the in vitro activity of tigecycline against 3,014 isolates of clinically important drug-resistant bacteria using the standard broth microdilution and disk diffusion methods. Species studied included methicillin-resistant Staphylococcus aureus (MRSA; n = 759), vancomycin-resistant Enterococcus faecium (VRE; n = 191), extended-spectrum β-lactamase (ESBL)-producing Escherichia coli (n = 602), ESBL-producing Klebsiella pneumoniae (n = 736), and Acinetobacter baumannii (n = 726) that had been collected from patients treated between 2008 and 2010 at 20 hospitals in Taiwan. MICs and inhibition zone diameters were interpreted according to the currently recommended U.S. Food and Drug Administration (FDA) criteria and the European Committee on Antimicrobial Susceptibility Testing (EUCAST) criteria. The MIC(90) values of tigecycline against MRSA, VRE, ESBL-producing E. coli, ESBL-producing K. pneumoniae, and A. baumannii were 0.5, 0.125, 0.5, 2, and 8 μg/ml, respectively. The total error rates between the two methods using the FDA criteria were high: 38.4% for ESBL-producing K. pneumoniae and 33.8% for A. baumannii. Using the EUCAST criteria, the total error rate was also high (54.6%) for A. baumannii isolates. The total error rates between these two methods were <5% for MRSA, VRE, and ESBL-producing E. coli. For routine susceptibility testing of ESBL-producing K. pneumoniae and A. baumannii against tigecycline, the broth microdilution method should be used because of the poor correlation of results between these two methods.
References
-
- Boucher HW, et al. 2009. Bad bugs, no drugs: no ESKAPE! An update from the Infectious Diseases Society of America. Clin. Infect. Dis. 48:1–12 - PubMed
-
- Clinical and Laboratory Standards Institute 2006. Performance standards for antimicrobial disk susceptibility tests: approved standard M2-A9, 9th ed Clinical and Laboratory Standards Institute, Wayne, PA
-
- Clinical and Laboratory Standards Institute 2006. Methods for dilution antimicrobial susceptibility tests for bacteria that grow aerobically: approved standard M7-A7, 7th ed Clinical and Laboratory Standards Institute, Wayne, PA
-
- Clinical and Laboratory Standards Institute 2011. Performance standards for antimicrobial susceptibility testing; 21st informational supplement, M100-S21 Clinical and Laboratory Standards Institute, Wayne, PA
-
- CLSI/NCCLS 2001. Development of in vitro susceptibility testing criteria and quality control parameters; approved guideline, 2nd ed NCCLS document M23-A2. National Committee for Clinical Laboratory Standards, Wayne, PA
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical